CDVSC7 & CDV7 Series Gas Fireplace
6
69D3011
GaS pReSSuReS
hIGh eleVaTIonS
Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z3.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installations at elevations
above 4,500 feet (1,370 m).
GaS SpeCIFICaTIonS & oRIFICe SIZe
CDVR SeRIeS
Max.Input Min. Input
Orifice
Model
Fuel
BTU/h
BTU/h
Size
CDVR33NV7
Nat.
18,000
13,000
#45
CDVR33NV117
Nat.
18,000
13,000
#45
CDVR33NE7
Nat.
18,000
13,000
#45
CDVR33NSC117 Nat.
18,000
13,000
#45
CDVR36NV7
Nat.
0,000
15,000
#44
CDVR36NE7
Nat.
0,000
15,000
#44
CDVR36NSC7
Nat.
0,000
15,000
#44
CDVR4NV7
Nat.
4,000
17,000
.35 mm
CDVR4NE7
Nat.
4,000
17,000
.35 mm
CDVR4NSC7
Nat.
4,000
17,000
.35 mm
CDVR47NV7
Nat.
4,000
17,000
.35 mm
CDVR47NE7
Nat.
4,000
17,000
.35 mm
CDVR47NSC7
Nat.
4,000
17,000
.35 mm
CDVR33PV7
LP
18,000
13,000
1.8 mm
CDVR33PV117
LP
17,000
14,000
1.5 mm
CDVR33PE7
LP
18,000
13,000
1.8 mm
CDVR33PSC117 LP
17,000
14,000
1.5 mm
CDVR36PV7
LP
0,000
15,000
1.35 mm
CDVR36PE7
LP
0,000
15,000
1.35 mm
CDVR36PSC7
LP
0,000
15,000
1.35 mm
CDVR4PV7
LP
4,000
18,000
1.45 mm
CDVR4PE7
LP
4,000
18,000
1.45 mm
CDVR4PSC7
LP
4,000
18,000
1.45 mm
CDVR47PV7
LP
4,000
18,000
1.45 mm
CDVR47PE7
LP
4,000
18,000
1.45 mm
CDVR47PSC7
LP
4,000
18,000
1.45 mm
Natural
Propane (LP)
Inlet Minimum
5.5” w.c.
11.0” w.c.
Inlet Maximum
14.0” w.c.
14.0” w.c.
Manifold Pressure
3.5” w.c.
10.0” w.c.
pRoDuCT FeaTuReS & GaS SpeCIFICaTIonS
GaS SpeCIFICaTIonS & oRIFICe SIZe
CDVT SeRIeS
Max.Input Min. Input
Orifice
Model
Fuel
BTU/h
BTU/h
Size
CDVT33NV7
Nat.
18,000
13,000
#45
CDVT33PV7
LP
18,000
13,000
1.8 mm
CDVT33NE7
Nat.
18,000
13,000
#45
CDVT33PE7
LP
18,000
13,000
1.8 mm
CDVT33NSC7 Nat.
18,000
13,000
#45
CDVT33PSC7 LP
18,000
13,000
1.8 mm
CDVT36NV7
Nat.
0,000
15,000
#44
CDVT36PV7
LP
0,000
15,000
1.35 mm
CDVT36NE7
Nat.
0,000
15,000
#44
CDVT36PE7
LP
0,000
15,000
1.35 mm
CDVT36NSC7 Nat.
0,000
15,000
#44
CDVT36PSC7 LP
0,000
15,000
1.35 mm
CDVT4NV7
Nat.
4,000
17,000
.35 mm
CDVT4PV7
LP
4,000
18,000
1.45 mm
CDVT4NE7
Nat.
4,000
17,000
.35 mm
CDVT4PE7
LP
4,000
18,000
1.45 mm
CDVT4NSC7 Nat.
4,000
17,000
.35 mm
CDVT4PSC7 LP
4,000
18,000
1.45 mm
CDVT47NV7
Nat.
4,000
17,000
.35 mm
CDVT47PV7
LP
4,000
18,000
1.45 mm
CDVT47NE7
Nat.
4,000
17,000
.35 mm
CDVT47PE7
LP
4,000
18,000
1.45 mm
CDVT47NSC7 Nat.
4,000
17,000
.35 mm
CDVT47PSC7 LP
4,000
18,000
1.45 mm
no
Te
ColD ClIMaTe InSulaTIon
If you live in a cold climate, seal all cracks
around your appliance, and wherever cold air
could enter the room, with noncombustible
material. It is especially important to insulate
the outside chase cavity between the studs
and under the floor on which the appliance
rests, if the floor is above ground level.
noTe:
Refer to cold climate pilot information on Page 43
for more information on standing pilot vs. intermittent pilot
options.