CFDV Series Gas Fireplace

48

20306739

BURNER, PILOT AND CONTROL 
COMPARTMENT

Keep the control compartment, logs, and burner areas 
surrounding the logs clean by vacuuming or brushing at 
least twice a year.  Make sure the burner porting, pilot air 
opening and burner air opening are free of obstructions 
at all times.

BURNER

Inspect area around the injector. Remove any lint or foreign 
material with a brush or vacuum.

VENT SYSTEM

The  fi replace and venting system should be inspected 
before initial use and at least annually by a qualifi ed fi eld 
service person. Inspect the external vent cap on a regular 
basis to make sure that no debris is interfering with the 
airfl ow. Inspect entire venting system to ensure proper 
function.

GLASS FRAME

Thoroughly clean the inside of the glass door after using 
the fi replace for ten hours. Periodically clean the glass as 
necessary. 

When cleaning the glass, remember:

 

Do not remove the glass when hot.

 Allow glass to 

cool before removal.

  NEVER use abrasive materials.

  Keep children and pets a safe distance away.

  Never operate the fi replace without the glass door 

properly secured.

  Never operate the fi replace if the glass is broken.

  Replace any glass that is chipped, cracked, or broken. 

Replacement glass frame assemblies MUST be sup-
plied by the fi replace manufacturer  – 

No substitute 

materials may be used.

 

Handle glass door with care to avoid striking or scratch-
ing it on hard objects.

To clean glass door, follow “Glass Removal” procedure 
outlined in the 

Final Installation 

section. Film deposit on the 

inside of the glass should be cleaned off using a nontoxic, 
non-corrosive, non-abrasive, mild-cleaning solution. Simply 
apply an adequate amount to the glass and wipe off with 
a damp cloth. After all maintenance has been completed, 
re-install glass door.

CLEANING AND MAINTENANCE

LOGS

Leave logs installed in the fi replace for cleaning. Vacuum 
surface of the logs with a brush attachment. If logs must 
be removed for cleaning, handle carefully by holding gently 
at each end. Gloves are recommended to prevent skin irri-
tation from ceramic fi bers. If skin becomes irritated, wash 
gently with soap and water. Vacuum surface of logs with 
brush attachment or brush logs with a soft bristle brush (i.e. 
clean, dry paintbrush). To place logs back in the fi replace, 
Refer to “Log Placement” section in this manual. 

NOTE: Do not use fl uids to clean ceramic fi ber logs.

ROCK WOOL

Replace or add rock wool as required following installa-
tion instructions in the  

Final Installation 

section of this 

manual. 

STONES AND FIREGLASS

Vacuum surface of the stones with a brush attachment. 
Fireglass can be removed (an empty wet/dry vac works well 
to gather up fi reglass) and washed with soap and water. 
Allow to dry thoroughly before placing back on the burner. 

Содержание 33CFDV(N/P)(V/I)SB

Страница 1: ...Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer servi...

Страница 2: ...BLOT 31 Optional Fan Blower System FK12 31 Operating Instructions Millivolt 32 For Your Safety Read Before Lighting 32 What To Do If You Smell Gas 32 Lighting Pilot for the First Time 32 Lighting Pilo...

Страница 3: ...all service or repair the fireplace Have burner system inspected annually by a qualified service person IMPORTANT SAFETY INFORMATION This fireplace is a vented product This fireplace must be properly...

Страница 4: ...t or any other accessory not approved for use with this fireplace 24 Do not operate appliance with the glass front removed cracked or broken Replacement of the glass should be done by a licensed quali...

Страница 5: ...S Natural Gas Propane LP Inlet Minimum 5 5 w c 11 0 w c Inlet Maximum 14 0 w c 14 0 w c Manifold Pressure 3 5 w c 10 0 w c Off Pilot On Knob Hi Lo Knob FP3011 FIREPLACE CONTROLS COLD CLIMATE OPTION IP...

Страница 6: ...ents and for firebox dimensions The framing headers may rest on the top of the firebox standoffs Do not bring headers below top of standoffs The firebox may be installed directly on a combustible floo...

Страница 7: ...343 4 883 mm D 27 689 mm 291 8 740 mm 331 8 841 mm E 18 457 mm 197 8 505 mm 197 8 505 mm F 157 8 430 mm 157 8 430 mm 157 8 430 mm G 211 8 537 mm 221 8 562 mm 261 2 673 mm H 231 4 591 mm 255 8 657 mm...

Страница 8: ...al codes includ ing permits and inspections The following factors should be taken into consideration Clearance to side wall ceiling woodwork and windows Minimum clearances to combustibles must be main...

Страница 9: ...ure fireplace to the floor Use four 4 screws to attach fireplace to framing The side nailing flanges are 1 2 or 5 8 to accommodate different wall thickness FINISHING MATERIAL NOTE Any wiring i e remot...

Страница 10: ...aside Figure 9 Remove Screws Remove Screws 7 Collar FP3022 Figure 9 Remove 7 Collar and Gasket 3 Remove the plate with the 4 collar and gasket by re moving four 4 screws Set aside Figure 10 4 Remove...

Страница 11: ...Gasket 7 Remove the small square plate and gasket by removing four 4 screws Set aside Figure 13 Remove Screws Small Square Plate FP3027 Figure 13 Remove Small Square Plate and Gasket 8 Install the pl...

Страница 12: ...h the side wall or vertical through the roof Only Vermont Castings Group venting components specifically approved and labeled for this fireplace may be used Flexible UL1777 listed venting may be used...

Страница 13: ...ances 100 000 BTU h 30kW 6 15cm for appliances 10 000 BTU h 3kW 9 23cm for appliances 10 000 BTU h 3kW and 50 000 BTU h 15kW 12 30cm for appliances 50 000 BTU h 15kW C Clearance to permanently closed...

Страница 14: ...ocal codes and or the current National Fuel Code ANSI Z223 1 NFPA 54 Canadian Installations The venting system must be installed in accordance with the current CSA B149 1 installation code FLEX VENT P...

Страница 15: ...assembly the joints we suggest put ting a lubricant Vaseline or similar on the male end of the twist lock pipe prior to assembly Male End Female End Screw Holes TWL100 Figure 18 Twist lock Pipe Joints...

Страница 16: ...and position the fire place in accordance with same EXAMPLE A If the vertical dimension from the floor of the unit is 11 3 4 m the horizontal run to the face of the outer wall must not exceed 14 4 3...

Страница 17: ...ARNING Rear Top Vent Vertical Side wall Horizontal sections of this vent system require a minimum of 3 76 mm clearances to combustibles at the top of the flue and 1 25 mm clearance at the sides and bo...

Страница 18: ...ombustible Walls Hole opening should be 71 2 191 mm diameter Step 2 Secure firestop to the inside frame center in the 95 8 x 95 8 vent opening Step 3 Measure the horizontal length requirement for the...

Страница 19: ...bus tible materials is 3 76 mm on top and 1 25 mm on the bottom and sides unless otherwise noted When vent termination exits through foundations less than 20 508 mm below siding outcrop the vent pipe...

Страница 20: ...run the length of the horizontal run MUST be reduced by 18 457 mm This does not apply if the 45 elbows are installed on the vertical part of the vent system The maximum number of elbow degrees in a sy...

Страница 21: ...ed flue restrictors onto the top edge of the firebox flue adapter according to the Vertical Side wall Installation Flue Restrictor Chart Step 1 Locate vent opening on the wall It may be necessary to f...

Страница 22: ...w Step 1 and 2 on Page 21 Step 3 Install the four 4 spacer springs on the 4 flex vent pipe When installing the spacer springs around the 4 pipe stretch the spring to approximately 15 381 mm wrap the s...

Страница 23: ...nting clearances are observed If venting system is installed below ground we rec ommend a window well with adequate and proper drainage to be installed around the termination area If installing a snor...

Страница 24: ...uced by 18 450 mm Example Maximum horizontal length No elbows 10 3 m 1 x 45 elbow 8 5 2 6 m 2 x 45 elbows 7 2 1 m A minimum of an 8 2 5 m vertical rise is required Two sets of 45 elbow offsets may be...

Страница 25: ...ual to 93 4 x 93 4 248 x 248 mm 4 Proceed to plumb for additional openings through the roof In all cases the opening must provide a minimum of 1 inch clearance to the vent pipe i e the hole must be at...

Страница 26: ...feet Flat to 6 12 1 0 Over 6 12 to 7 12 1 25 Over 7 12 to 8 12 1 5 Over 8 12 to 9 12 2 0 Over 9 12 to 10 12 2 5 Over 10 12 to 11 12 3 25 Over 11 12 to 12 12 4 0 H Minimum height from roof to lowest d...

Страница 27: ...o between 11 and 13 inches of water If you do not reduce incoming gas pressure burner system regula tor damage could occur Install external regulator with the vent pointing down as shown in Figure 51...

Страница 28: ...t lightly to male threads This will prevent excess sealant from going into pipe Excess seal ant in pipe could result in clogged burner system valve We recommend that you install a sediment trap drip l...

Страница 29: ...he factory 3 The junction box cover has a factory installed romex style strain relief connector After connecting the wires route the wire leads through this connector Refer to the wiring diagram in Fi...

Страница 30: ...m for Wall Switch ELECTRICAL INSTALLATION MILLIVOLT REMOTE WALL SWITCH Position the wall switch Do not extend beyond the 15 feet of wire OPTIONAL DC REMOTE SYSTEMS See section entitled Hearth Mount in...

Страница 31: ...ed This system requires that 110 120 VAC to be wired to the factory installed junction box before the fireplace is permanently installed Figure 56 Black Black Green Black Black White Thermostatic Swit...

Страница 32: ...ified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician...

Страница 33: ...1 and 2 LIGHTING PILOT Pilot Position Check for gas leaks in each of the following locations Pipe from the gas supply line connection to the gas valve Burner connections Field made joints gas shutoff...

Страница 34: ...position It will take less than four 4 seconds for the burner to ignite MAIN BURNER SWITCH This switch allows you to turn on and to turn off the main burner without using the gas valve knob is in the...

Страница 35: ...ot use open flame to check for gas leaks ELECTRICAL WIRING General 1 This fireplace is equipped with an IPI control valve which operates on 6 volts The 6 volt DC adapter plugs into the fireplace junct...

Страница 36: ...leads through this connector Refer to the wiring diagram in Figure 59 Figure 59 Junction Box Wiring Diagram Junction Box Factory Supplied Not Supplied 120V AC 60Hz ELECTRICAL INSTALLATION IPI WALL SW...

Страница 37: ...Switch DC Power Green Ground Gas In Gas Out Pilot Gas Tubing Valve Cold Climate Switch Main Switch ELECTRICAL INSTALLATION IPI CAUTION Electrical connections should only be performedbyaqualified lice...

Страница 38: ...one Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the fire department C Turn Master Switch to ON position by hand Never use tools If the switch will not function b...

Страница 39: ...ow B in the safety information on Page 38 If you do not smell gas go to next step 4 Press the wall switch to the ON position Sparker will spark and pilot flame will light 5 Once pilot flame is establi...

Страница 40: ...il Two RED 1 time No Sensor Signal Three RED 1 time Trial Lockout One GREEN every 2 seconds until manual reset Flames Loss Lockout One RED GREEN every 2 seconds until manual reset AC Power On GREEN So...

Страница 41: ...elease the two 2 latches on the top of the fireplace by pulling forward and up Figure 61 3 Tilt glass frame out and lift glass frame up and away Figure 62 4 Set glass frame aside Figure 62 Remove Safe...

Страница 42: ...is blue and only in the center turn off unit and let cool After unit is cool remove logs and check to make sure rock wool is placed correctly Replace logs NOTE The type of installation vent system con...

Страница 43: ...eld 3 Install the center firebrick panel on the back wall first Stand firebrick panel straight up against the back of fireplace with the bottom edge at bottom of inner firebox 4 Repeat Step 3 with the...

Страница 44: ...tab in the center front of the false hearth up to a 90 angle Figure 71 Place the top log 4 by resting the square notch located on the bottom of the log over the tab mentioned above Rest the top part...

Страница 45: ...Center Tab Figure 71 LG1183 Figure 73 WARNING Do not sprinkle the lava rock on top of the burner This may cause potential sooting glass breakage and a fire hazard LAVA ROCK PLACEMENT Sprinkle lava ro...

Страница 46: ...g the latches on top of the fireplaces and tilting frame for ward Lift off and set aside 4 Remove the logs if they are installed Vacuum the rock wool off the burner 5 Remove the four 4 pin log plate a...

Страница 47: ...duals If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this appliance Any safety screen guard or barrier removed for servicing the appliance must be rep...

Страница 48: ...eplace manufacturer No substitute materials may be used Handle glass door with care to avoid striking or scratch ing it on hard objects To clean glass door follow Glass Removal procedure outlined in t...

Страница 49: ...re that the thermocouple connection at the gas valve is fully inserted and tight Disconnect the thermocouple from the valve place one millivolt lead wire on the tip of the thermocouple and the other m...

Страница 50: ...ss does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage low Using battery Check valve connections Check power supply go through A...

Страница 51: ...Glass Kit Diamond GKD Glass Kit Onyx GKO Glass Kit Sapphire GKS Blower Kits T Stat Blower w Speed Control BLOT Manual Blower FK12 Speed Control 26D0746 SYMPTOM POSSIBLE CAUSE ACTION The pilot and mai...

Страница 52: ...6161K 20306695K 20306701K Kits Sold Separately 3 Blower 1 BLOT BLOT BLOT 4 Firebrick Kit Cottage Clay 1 FB33CFDVCC FB36CFDVCC FB42CFDVCC 4 Firebrick Kit Cottage Red 1 FB33CFDVCR FB36CFDVCR FB42CFDVCR...

Страница 53: ...Pilot Assembly 1 37D0018K 37D0019K 37D0018K 37D0019K 37D0018K 37D0019K 5 Replacement Thermocouple 1 24D0808 24D0808 24D0808 24D0808 24D0808 24D0808 6 Replacement Igniter and Wire 1 10001297 10001297 1...

Страница 54: ...E0101 95E0101 95E0101 4 Pilot Assembly 1 95E0103 95D0104 95E0103 95E0104 95E0103 95E0104 5 Control Board 1 95E0108 95E0108 95E0108 95E0108 95E0108 95E0108 6 Injector 1 58D0061 62D3005 59D0062 20H3146...

Страница 55: ...ck Pipe 20 Rigid Pipe single pack 7TDVP20 30 Flex Pipe single pack 7FDVP30 12 18 Adjustable Vent Length 7TDVP1218 35 64 Adjustable Vent Length 7TDVP3564 8 Vent Pipe 4 pack 7TDVP8 4 12 Vent Pipe 4 pack...

Страница 56: ...ination Screen Guard 7TBSG Up and Out Starter Kit w 40 Flex Pipe Firestop Cool 7FDVSCTK Touch Termination w Siding Shield and 2 ea Clamp Bands Twist Lock Pipe 20 Termination Pipe 8 pack 7TDVP20 8 10 1...

Страница 57: ...pipe length galvanized 46DVA 12 3 6 24 pipe length galvanized 46DVA 24 3 6 36 pipe length galvanized 46DVA 36 3 6 48 pipe length galvanized 46DVA 48 4 6 81 2 pipe length galvanized 46DVA 08A 4 6 16 p...

Страница 58: ...o comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed MASSACHUSETTS RESIDENTS ONLY 2...

Страница 59: ...Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage...

Страница 60: ...EL ENERGUIDE RATINGS FIREPLACE EFFICIENCY PERCENTAGE D O E AFUE PERCENTAGE 33CFDVNV 58 3 59 70 33CFDVPV 67 1 63 83 33CFDVNI 61 9 59 70 33CFDVPI 72 6 63 83 36CFDVNV 63 0 62 01 36CFDVPV 67 7 66 16 36CFD...

Отзывы: