background image

 

18”‐24”‐30” Kiva Fireplace 

GAS BURNING INSTALLATION MANUAL 

WITH DOUBLE WALL AIR‐COOLED CHIMNEY 

 

Keep these instructions for future use. 

This fireplace is to be installed ONLY by a con‐
struction  industry  licensed  contractor.  Any 
permits and construction industry inspections 
required  for  installation  should  be  obtained 
by this contractor. 

A)  KIVA  FIREBOX 

‐ A pre‐cast firebox consist‐

ing  of  real  hand  laid  firebrick  and  light‐
weight concrete. 

 

B)  EXTERIOR  FIREPLACE  FRAME 

‐  A  tubular 

steel and diamond‐mesh frame. The frame 
is finished with stucco after installation.  

 

C)  AIR‐COOLED  CHIMNEY 

‐  Lightweight     

stainless  steel  double  walled  air‐cooled 
chimney is used for venting the fireplace. 

 

D)  GAS  LOG  SYSTEM 

‐ Electronic Ignition Gas 

Log  Burning  System  is  operated  by  a  wall 
switch or remote. 

 

E)  FIREBOX  PEDESTAL 

‐  Concrete  blocks  are 

used to elevate the firebox.  

NOTE: 

All 

warnings

 are outlined in this manual and must be adhered to by the installer 

and the buyer. Failure to do so will nullify the manufacturer’s warranty, and may cause 
serious fire hazard. 

The Adobelite Fireplace System consists of: 

Frame Models: 

Orno 

 

 

 

Santa Fe 

 

 

 

Navajo 

 

 

 

Zuni 

RV‐4.10.2019 

Содержание KIVA 18 Ornito

Страница 1: ...lar steel and diamond mesh frame The frame is finished with stucco after installation C AIR COOLED CHIMNEY Lightweight stainless steel double walled air cooled chimney is used for venting the fireplac...

Страница 2: ...2 This page intentionally left blank...

Страница 3: ...Manual Combustion Air Intake of fireplace must be kept clear of debris at all times This fireplace is to be installed ONLY by a construction industry licensed contractor Any permits and construction i...

Страница 4: ...4 This page intentionally left blank...

Страница 5: ...Fireplace Layout 10 11 Fireplace Pedestal 11 2 Firebox Installation 12 Firebox Assembly 12 Door Frame 13 Anchor Plate 13 3 Chimney Installation 14 Installing the Chimney Pipe 14 17 Outside Air Kit In...

Страница 6: ...___________ Dealership Purchased at ______________________________________ Dealership Phone __________________________________________ Date Purchased ________________ Date Installed __________________...

Страница 7: ...TO COMBUSTIBLES SIDES BACK 1 FACE All framing along firebox face must be non combustible HEARTH EXTENTION 18 CHIMNEY 2 KIVA24 FIREBOX DIMENSIONS TOP VIEW A B C D E F G H I KIVA 24 25 1 4 34 25 44 52 2...

Страница 8: ...00 WARNING B Vent Chimney should never be used when solid fuels are to be burned TABLE 1 chimney requirements KIVA30 FIREBOX DIMENSIONS TOP VIEW A B C D E F G H I KIVA 30 30 40 27 1 4 48 1 2 56 1 2 28...

Страница 9: ...ural Gas and 39 700 for Liquid Propane STUB OUT Before the Adobelite firebox is installed gas lines should be run into the area where the fireplace will be in stalled A Keyed Gas Shutoff Valve is requ...

Страница 10: ...an Electrical Box and Wall Switch or remote control receiver for fireplace control in the wall at the desired location Refer to FIG 1 on page 9 to locate the minimum distance from the corner that the...

Страница 11: ...shown in FIG 6 or any other combination of concrete blocks can also be used as long as the overall height is 12 1 Two columns of CMU s should be positioned with the front edge of the blocks against th...

Страница 12: ...eces will meet and align the back and sides of the pieces 5 FRONT ARCH Apply refractory mortar to the front edges of the Lower and Upper Back pieces and to the top of the Front Arch sec tion Place the...

Страница 13: ...refractory mortar to the top of firebox where the Anchor Plate will sit Align the back edge of the Anchor Plate opening with opening in the firebox top section Secure the Anchor Plate using four dia x...

Страница 14: ...The Starter Collar is used to support the outer chimney section while the Anchor Plate collar supports the inner chimney Attach the legs of the Starter Collar to the Anchor Plate with the supplied 12...

Страница 15: ...ensions A and E in Layout charts Pages 10 11 Firmly push both the in ner and outer pipes into the Starter Elbow until they snap lock into place 14 RETURN ELBOW Position the Return Elbow so that the ch...

Страница 16: ...Firestop Spacers are required at each point where the chimney penetrates a floor or ceil ing joist space Attach Firestop Spacer to joist using wood screws If the chimney pipe passes through a framed o...

Страница 17: ...tion air to the firebox therefore not using air from the interior of the house as well as cooling the gas control system 20 4 HOLE FIG 20 1 OUTSIDE AIR VENT EXTERIOR WALL FIG 21 ALUMINUM FLEX DUCT 21...

Страница 18: ...UAL IS NOT FOLLOWED EXACTLY A FIRE OR EPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE 22 ATTACHING BURNER PAN AND PILOT Screw the fe male flare fitting on the end of the su...

Страница 19: ...g Next cut several strips of diamond lath mesh 16 wide Place the lath strips against the inside Front Arch even with the Door Frame FIG 24 Using 15 8 washer head screws attach the lath to the Front Ar...

Страница 20: ...ay not contain sand and cement Many indoor plasters are gypsum based Apply the 2nd coat using a trowel and then smooth out the plaster using water and a float or sponge When complete the 2nd coat will...

Страница 21: ...ear the supplied Glowing Embers into dime sized pieces Place the pieces all around the burner holes on top of the burner pan making sure not to cover the burn holes where the gas will come out of See...

Страница 22: ...T WHAT TO DO IF YOU SMELL GAS 1 Shut off gas to fireplace 2 Extinguish and flame 3 Go to a phone outside your home and call your gas supplier If you can t reach your gas supplier call the Fire Departm...

Страница 23: ...a Frame hearth extension and are available in lengths of 2 to 10 Specify left or rights side when ordering Wood Storage Bin The Wood Storage Bin has an interior size of 24 wide x 12 high x 16 deep It...

Отзывы: