LAYOUT (FIG. 4, FIG. 5) 

CARPET 

Carpet and padding will need to be removed up to the hearth line. See FIG. 4 and FIG. 5 below. 

 

 

Begin the layout by drawing a center line at 45 degrees for a corner installation, or perpendicular to the wall for 
a flat‐wall installation. Next, draw the baseline (dimension D ‐ refer to FIG. 4 below and FIG. 5 on page 11) per‐
pendicular to the center line. The base line will be aligned with the front edge of the Firebox Base and the Fire‐
box Pedestal.  

 

CORNER LAYOUT  

18” FIREBOX MODELS 

MODEL 

Ornito 

2’0” 

2’10” 

4’1” 

2’4” 

Santa Fe 

2’0” 

3’3” 

4’6” 

2’4” 

 

Frame at   

Ceiling 

Frame at 

Hearth 

Hearth 

Baseline 

24” FIREBOX MODELS 

MODEL 

Orno 

2’2” 

3’2” 

4’6” 

2’5” 

Santa Fe 

2’0” 

3’3” 

4’7” 

2’5” 

 

Frame at   

Ceiling 

Frame at 

Hearth 

Hearth 

Baseline 

Navajo 

2’0” 

3’9” 

4’7” 

2’5” 

Zuni 

2’0” 

4’0” 

5’4” 

2’5” 

30” FIREBOX MODELS 

MODEL 

 

Frame at   

Ceiling 

Frame at 

Hearth 

Hearth 

Baseline 

Orno 

2’6” 

3’6” 

4’10” 

2’9” 

Santa Fe 

2’5” 

3’8” 

5’0” 

2’9” 

Navajo 

2’5” 

4’2” 

5’0” 

2’9” 

Zuni 

2’5” 

4’2” 

5’6” 

2’9” 

CENTER LINE 

BASE LINE 

FIG. 4 ‐ 

CORNER LAYOUT  

ELECTRICAL REQUIREMENTS: 

ELECTRICAL BOX AND SWITCH 

Install  an  Electrical  Box  and  Wall  Switch  (or  remote  control  receiver)  for  fireplace  control  in  the  wall  at  the      
desired  location.  Refer  to  FIG.  1  on  page  9  to  locate  the  minimum  distance  from  the  corner  that  the  Switch 
should  be  located.  DO  NOT  CONNECT  110V  AC  to  the  wall  switch.  This  wall  switch  will  connect  to  the  low‐
voltage 20AWG of the gas system. 8 Feet of 20 AWG Milli‐volt wire is included prewired to the gas system con‐
trols, which is to be connected to the switch terminals.  

WARNING: 

 LOW VOLTAGE AND 110 VAC VOLTAGE CANNOT SHARE THE SAME ELECTRICAL BOX 

This fireplace comes equipped with a 3 volt electronic ignition gas control system. This system includes a two     
D‐cell battery pack prewired to the gas system controls, which will provide reliable operation of the system even 
in the event of a power outage. Battery polarity must be correct or module damage will occur. An optional 3 volt 
AC transformer is available from Adobelite or your dealer for operation using 110V AC. The optional transformer 
and the included battery pack CANNOT both be hooked up to the control module at the same time or damage 
will occur. Remove batteries from the battery pack before connecting the optional transformer, and unplug the 
transformer before installing the batteries. 

10 

Содержание KIVA 18 Ornito

Страница 1: ...lar steel and diamond mesh frame The frame is finished with stucco after installation C AIR COOLED CHIMNEY Lightweight stainless steel double walled air cooled chimney is used for venting the fireplac...

Страница 2: ...2 This page intentionally left blank...

Страница 3: ...Manual Combustion Air Intake of fireplace must be kept clear of debris at all times This fireplace is to be installed ONLY by a construction industry licensed contractor Any permits and construction i...

Страница 4: ...4 This page intentionally left blank...

Страница 5: ...Fireplace Layout 10 11 Fireplace Pedestal 11 2 Firebox Installation 12 Firebox Assembly 12 Door Frame 13 Anchor Plate 13 3 Chimney Installation 14 Installing the Chimney Pipe 14 17 Outside Air Kit In...

Страница 6: ...___________ Dealership Purchased at ______________________________________ Dealership Phone __________________________________________ Date Purchased ________________ Date Installed __________________...

Страница 7: ...TO COMBUSTIBLES SIDES BACK 1 FACE All framing along firebox face must be non combustible HEARTH EXTENTION 18 CHIMNEY 2 KIVA24 FIREBOX DIMENSIONS TOP VIEW A B C D E F G H I KIVA 24 25 1 4 34 25 44 52 2...

Страница 8: ...00 WARNING B Vent Chimney should never be used when solid fuels are to be burned TABLE 1 chimney requirements KIVA30 FIREBOX DIMENSIONS TOP VIEW A B C D E F G H I KIVA 30 30 40 27 1 4 48 1 2 56 1 2 28...

Страница 9: ...ural Gas and 39 700 for Liquid Propane STUB OUT Before the Adobelite firebox is installed gas lines should be run into the area where the fireplace will be in stalled A Keyed Gas Shutoff Valve is requ...

Страница 10: ...an Electrical Box and Wall Switch or remote control receiver for fireplace control in the wall at the desired location Refer to FIG 1 on page 9 to locate the minimum distance from the corner that the...

Страница 11: ...shown in FIG 6 or any other combination of concrete blocks can also be used as long as the overall height is 12 1 Two columns of CMU s should be positioned with the front edge of the blocks against th...

Страница 12: ...eces will meet and align the back and sides of the pieces 5 FRONT ARCH Apply refractory mortar to the front edges of the Lower and Upper Back pieces and to the top of the Front Arch sec tion Place the...

Страница 13: ...refractory mortar to the top of firebox where the Anchor Plate will sit Align the back edge of the Anchor Plate opening with opening in the firebox top section Secure the Anchor Plate using four dia x...

Страница 14: ...The Starter Collar is used to support the outer chimney section while the Anchor Plate collar supports the inner chimney Attach the legs of the Starter Collar to the Anchor Plate with the supplied 12...

Страница 15: ...ensions A and E in Layout charts Pages 10 11 Firmly push both the in ner and outer pipes into the Starter Elbow until they snap lock into place 14 RETURN ELBOW Position the Return Elbow so that the ch...

Страница 16: ...Firestop Spacers are required at each point where the chimney penetrates a floor or ceil ing joist space Attach Firestop Spacer to joist using wood screws If the chimney pipe passes through a framed o...

Страница 17: ...tion air to the firebox therefore not using air from the interior of the house as well as cooling the gas control system 20 4 HOLE FIG 20 1 OUTSIDE AIR VENT EXTERIOR WALL FIG 21 ALUMINUM FLEX DUCT 21...

Страница 18: ...UAL IS NOT FOLLOWED EXACTLY A FIRE OR EPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE 22 ATTACHING BURNER PAN AND PILOT Screw the fe male flare fitting on the end of the su...

Страница 19: ...g Next cut several strips of diamond lath mesh 16 wide Place the lath strips against the inside Front Arch even with the Door Frame FIG 24 Using 15 8 washer head screws attach the lath to the Front Ar...

Страница 20: ...ay not contain sand and cement Many indoor plasters are gypsum based Apply the 2nd coat using a trowel and then smooth out the plaster using water and a float or sponge When complete the 2nd coat will...

Страница 21: ...ear the supplied Glowing Embers into dime sized pieces Place the pieces all around the burner holes on top of the burner pan making sure not to cover the burn holes where the gas will come out of See...

Страница 22: ...T WHAT TO DO IF YOU SMELL GAS 1 Shut off gas to fireplace 2 Extinguish and flame 3 Go to a phone outside your home and call your gas supplier If you can t reach your gas supplier call the Fire Departm...

Страница 23: ...a Frame hearth extension and are available in lengths of 2 to 10 Specify left or rights side when ordering Wood Storage Bin The Wood Storage Bin has an interior size of 24 wide x 12 high x 16 deep It...

Отзывы: