LED Light
Components required from Bag # 915436:
• Hub Covering Plate (1)
• LED Light Assembly (1)
• LED Light Mounting Bracket (1)
• 1/4 in. – 20 x 3/4 in. Grade 5 Hex Bolt (6)
• M10 – 1.5 x 20 in. Grade 8.8 Hex Bolt (1)
• 3/8 in. Washer (1)
Hardware/Tools Needed (Not Included):
• Torque Wrench
• 17mm Socket
• 3/8 in. Magnetic Nut Driver
• Magnetic Nut Driver Extension
• Impact Driver
1. Use the supplied M10 – 1.5 x 20 in. grade 8.8 hex
bolt and 3/8 in. washer to attach the LED light
mounting bracket and light shroud to the light.
2. Insert the LED light mounting bracket into the
cut-out of the hub covering plate. Allow the hub
covering plate to sit on the top of the LED light
assembly.
3. Lift the LED light assembly and hub covering plate
until the u-nuts on the LED light mounting bracket
are aligned with the mounting holes in the hub
retention bracket. Install (2) 1/4 in. – 20 x 3/4 in.
grade 5 hex bolts into the u-nuts using a magnetic
nut driver extension and impact driver. Torque to
120 in∙lbf (13.6 N∙m).
4. Connect the male light
power (3 pin) and light
communication (2 pin) plugs
from the LED light assembly
to their corresponding female
connectors in the motor.
NOTE:
The LED light assembly can be pivoted out of
the way to simplify connection of the light power and
light communication plugs.
5. Raise the hub covering plate until the holes in
the plate are aligned with the u-nuts on the hub
retention bracket. Install (4) 1/4 in. – 20 x 3/4 in.
grade 5 hex bolts into the u-nuts. Torque to
96 in∙lbf (10.8 N∙m).
LIGHT POWER PLUG
HUB COVERING
PLATE
HUB RETENTION
BRACKET
U-NUT
LIGHT BRACKET
LIGHT POWER PLUG
LED LIGHT ASSEMBLY
LIGHT COMMUNICATION PLUG
U-NUT
1/4 in. - 20 x 3/4 in. GRADE 5 HEX BOLT
(6 PER ASSEMBLY)
LIGHT COMMUNICATION PLUG
1/4 in. - 20 x 3/4 in. GRADE 5 HEX BOLT
M10 - 1-1/2 x 20 in. GRADE 8 HEX BOLT
3/8 in. WASHER
6. Using the attached 115v light power cable located
at the top of the downtube, wire the LED light
into the buildings light grid. Be sure to follow all
national and local codes for electrical installation.
Light Relay
Components required (included):
• Light relay Kit for HVLS control
Hardware/Tools (Not Included):
• Standard Screwdriver
• Wire Strippers
1. Land the white 0-10 input wire to the relay from the
drive of the fan.
2. Using the wiring diagram below, land the line and
neutral input power to the relay along with running
line and neutral output power to the light kit.
LIGHT RELAY
+ TO LIGHT (BROWN)
- TO LIGHT (BLUE)
BLACK (LINE)
WHITE (N)
0-10V (+) (BLUE)
0-10V (-) (WHITE)
POWER SOURCE
L1
L2/N
GROUND
LIGHT POWER
BLACK (LINE)
WHITE (N)
LIGHT CONTROL
RED (0-10V)
BLACK (GROUND)
GREEN (GROUND)
LED Light Installation (Optional)
LIGHT POWER PLUG
HUB COVERING
PLATE
HUB RETENTION
BRACKET
U-NUT
LIGHT BRACKET
LIGHT POWER PLUG
LED LIGHT ASSEMBLY
LIGHT COMMUNICATION PLUG
U-NUT
1/4 in. - 20 x 3/4 GRADE 5 HEX BOLT
(6 PER ASSEMBLY)
LIGHT COMMUNICATION PLUG
1/4 in. - 20 x 3/4 GRADE 5 HEX BOLT
M10 - 1-1/2 x 20 GRADE 8 HEX BOLT
3/8 in. WASHER
High Volume, Low Speed Ceiling Fans
17