![VENCO VCFI Series Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/venco/vcfi-series/vcfi-series_installation-operation-and-maintenance-manual_4042084010.webp)
Components required from Bag # 915065:
• Motor/Hub Assembly (1)
• Rear VFD Cover (1)
• 3/8 in. – 16 x 2-3/4 in. Grade 8 Hex Bolt (2)
• M4 – 0.7 x 10 Machine Screw (4)
Hardware/Tools Needed (Not Included):
• 9/16 in. Socket
• Socket Wrench
• Torque Wrench
• Phillips Screwdriver
• Lifting Equipment
• Cribbing (optional)
• Awl (optional)
DANGER
Always disconnect, lock and tag power source before
installing or servicing. Failure to disconnect power
source can result in fire, shock or serious injury.
DANGER
Pour écarter les risques d’incendie, de choc électrique
ou de blessure grave, veiller à toujours débrancher,
verrouiller et étiqueter la source de courant avant
l’installation ou l’entretien.
1. Using a scissor lift or other suitable lifting device,
lift the motor/hub assembly by resting the struts on
the lift structure or cribbing.
FRONT VFD COVER
DOWNTUBE AND MOUNT ASSEMBLY
MOTOR AND HUB ASSEMBLY
2. Feed the safety retention cable that is attached to
the motor/hub assembly up through the bottom
of the downtube until the loose end of the safety
cable is accessible at the top of the downtube. Pull
the loose end of the safety retention cable from the
top of the downtube until all of the slack is pulled
through.
3. If fan was supplied with the optional LED light
assembly, connect the male light power (3 pin) and
light communication (2 pin) plugs in the
motor/hub assembly to their corresponding female
connectors in the downtube.
DOWNTUBE AND MOUNT ASSEMBLY
MOTOR & HUB ASSEMBLY
LIGHT POWER PLUG
(OPTIONAL)
LIGHT COMMUNICATION PLUG
(OPTIONAL)
LIGHT POWER PLUG
(OPTIONAL)
LIGHT COMMUNICATION PLUG
(OPTIONAL)
SAFETY RETENTION CABLE
MOTOR POWER, GROUND AND
COMMUNICATION CABLES
4. Using a Phillips screwdriver, remove the front VFD
cover and set aside.
5. Carefully align the motor axle with the downtube
opening, making sure that the wires protruding
from the motor axle are on the same side as the
exposed circuit board of the VFD.
6. Slowly lift the motor/hub assembly until the motor
axle is nested inside the downtube. Take care
to align the motor axle holes with the downtube
holes.
IMPORTANT:
Do not allow safety cable or wiring to
be crushed while lifting the motor/hub assembly into
the downtube. Safety cable and wiring must be kept
taut inside the downtube in order to prevent damage. If
either the safety cable or the wiring are damaged during
installation, contact your local rep or the manufacturer.
MOTOR AND HUB ASSEMBLY
DOWNTUBE AND MOUNT ASSEMBLY
7. Install the supplied (2) 3/8 in. – 16 x 2-3/4 in. grade
8 hex bolts into the locknuts attached to the
downtube. Torque the bolts to a value of 33 ft∙lbf
(44.75 N∙m).
NOTE:
The attached locknuts are not visible while the
VFD is installed on the downtube of the fan.
MOTOR AND HUB ASSEMBLY
DOWNTUBE AND MOUNT ASSEMBLY
3/8 in. - 16 x 2-3/4 in. GRADE 8 HEX BOLT
Motor/Hub to Downtube Installation
High Volume, Low Speed Ceiling Fans
10