Models VCFI-3 and VCFI-6 are the ideal choice for providing year-round comfort in air circulation and destratification 
applications. Featuring an aerodynamic, extruded aluminum airfoil design and a high efficiency direct drive motor, 
model VCFI delivers maximum airflow at a fraction of the operating cost of other HVLS fans. And, with its universal 
ceiling mount, the VCFI fan is the easiest HVLS fan to install in the market!

IMPORTANT: 

To reduce the risk of fire, electric shock, 

or injury to persons, Model VCFI fans must be installed 
with a mount assembly, motor assembly and airfoils that 
are marked (on their cartons) to indicate suitability with 
this model. Other mounts, motors, and airfoils cannot 
be substituted.

WARNING

To reduce the risk of fire, electric shock, or injury to 
persons, observe the following:
  1.  Use this unit only in the manner intended by the 

manufacturer. If you have questions, contact the 
manufacturer.

  2.  Before servicing or cleaning unit, switch 

power off at service panel and lock the service 
disconnecting means to prevent power from 
being switched on accidentally. When the service 
disconnecting means cannot be locked, securely 
fasten a prominent warning device, such as a tag, 
to the service panel.

WARNING

To reduce the risk of fire, electric shock, or injury to 
persons, observe the following:
  1.  Installation work and electrical wiring must be 

done by qualified person(s) in accordance with all 
applicable codes and standards, including fire-
rated construction.

  2.  When cutting or drilling into wall or ceiling, do 

not damage electrical wiring and other hidden 
utilities.

WARNING

This appliance can be used by children aged from 8 
years and above and persons with reduced physical, 
sensory or mental capabilities or lack of experience 
and knowledge if they have been given supervision or 
instruction concerning use of the appliance in a safe 
way and understand the hazards involved. Children 
shall not play with the appliance. Cleaning and user 
maintenance shall not be made by children without 
supervision.

General Safety Information

IMPORTANT: 

VCFI fans must be installed with the supplied CAT-5e communication cable or shielded CAT-5e 

(by others) that complies with the following specifications. Cable must be twisted pair, shielded 26 ga. CAT-5e 
cable with a drain wire and must be compliant with ISO 11801. Cable must use shielded RJ45 connectors with 
a soldered drain and wiring configuration must follow EIA/TIA T568B wiring pinout. Individual CAT-5e cable 
lengths must not exceed 200 ft. in order to prevent network communication issues.

High Volume, Low Speed Ceiling Fans

1

Installation, Operation and Maintenance Manual

Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, 
operate or maintain the product described. Protect yourself and others by observing all safety information. Failure 
to comply with these instructions will result in voiding of the product warranty and may result in personal injury 
and/or property damage.

Document 483907 

Model VCFI

High Volume, Low Speed Ceiling Fans

Содержание VCFI Series

Страница 1: ...tandards including fire rated construction 2 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities WARNING This appliance can be used by children age...

Страница 2: ...e Protection Agency NFPA where applicable Follow the Canadian Electric Code CEC in Canada 2 The rotation of the impeller is critical It must be free to rotate without striking or rubbing any stationar...

Страница 3: ...nal use consider using Tectyl 511M Rust Preventive WD 40 or the equivalent Removing from Storage As fans are removed from storage to be installed in their final location they should be protected and m...

Страница 4: ...d location of the fan s 10 Before installation it is important to verify that the mounting surface will bear the operating weight and maximum torque twisting force of the unit The Structural Engineer...

Страница 5: ...INGLET POWER CABLE PLUG OPTIONAL LIGHT POWER CABLE OPTIONAL SAFETY CABLE WITH NO 4 GRIPPLE FACTORY INSTALLED VFD FIRE ALARM LANDING POINT COMMUNICATION CABLE WITH RJ45 SPLITTER LIGHT POWER PLUG OPTION...

Страница 6: ...BE MOUNT ASSEMBLY HEX BOLT I Beam Clamping Plate 2 I Beam Clamping Plate Shim 2 I BEAM CLAMPING PLATE I BEAM CLAMPING PLATE SHIM UNIVERSAL MOUNTING PLATE 1 2 in WASHER 1 2 in 13 GRADE 8 NYLON LOCKNUT...

Страница 7: ...o one side of the I beam and tighten hardware until the universal mounting plate is snug against the beam but can still be moved approximately 1 4 in of the bolt threads exposed below the nylon locknu...

Страница 8: ...Kit For Beams 4 1 2 8 7 8 in Wide Components required from Bag 915429 Wood Beam Bracket 2 1 2 in 13 x 1 1 2 in Grade 8 Hex Bolt 4 1 2 in 13 Grade 8 Nylon Locknut 8 1 2 in Washer 16 Hardware Tools Nee...

Страница 9: ...STEEL ANGLES BY OTHERS 1 2 in 13 x 1 3 4 in GRADE 8 HEX BOLT Z PURLIN 1 2 in WASHER Z PURLIN BRACKET 1 2 in 13 GRADE 8 NYLON LOCKNUT TORQUE TO 80 FT LBF 108 5 N m TORQUE TO 80 FT LBF 108 5 N m 5 Using...

Страница 10: ...motor hub assembly to their corresponding female connectors in the downtube DOWNTUBE AND MOUNT ASSEMBLY MOTOR HUB ASSEMBLY LIGHT POWER PLUG OPTIONAL LIGHT COMMUNICATION PLUG OPTIONAL LIGHT POWER PLUG...

Страница 11: ...1 5 on dipswitch 3 to set the desired Modbus address A table with all possible Modbus addresses is shown to the right IMPORTANT Positions 6 8 are used to set parameters needed for fan operation and sh...

Страница 12: ...e mounting structure referred to as the live end 4 Attach the dead end of the safety cable to the live end using the supplied 0 188 in u bolt steel cable IMPORTANT The first steel cable clamp must be...

Страница 13: ...Insert the loose end of the safety cable into the No 4 Gripple connector Note that the cable will only feed through the Gripple connector in one direction marked on the Gripple connector with an arrow...

Страница 14: ...ing IMPORTANT Steel cable clamps consist of two parts the u bolt and the saddle Steel cable clamps must be installed with the u bolt over the dead end of the guy wire and the saddle over the live end...

Страница 15: ...e that the fan is level in all directions 5 Cut or organize excess guy wires to ensure that they do not interfere with fan rotation NOTE If necessary the guy wires can be loosened by inserting the lon...

Страница 16: ...on locknuts per blade as shown below Hand tighten hardware 5 16 in WASHER 2 PER BLADE 5 16 in 18 GRADE 8 NYLON LOCKNUT 2 PER BLADE MOTOR HUB ASSEMBLY 5 16 in 18 x 2 in GRADE 8 HEX BOLT 2 PER BLADE MOT...

Страница 17: ...b retention bracket Install 4 1 4 in 20 x 3 4 in grade 5 hex bolts into the u nuts Torque to 96 in lbf 10 8 N m LIGHT POWER PLUG HUB COVERING PLATE HUB RETENTION BRACKET U NUT LIGHT BRACKET LIGHT POWE...

Страница 18: ...Communication Wiring Fan Control Installation IMPORTANT VCFI fans must be installed with the supplied CAT 5e communication cable or shielded CAT 5e by others that complies with the following specifica...

Страница 19: ...shock or serious injury DANGER Pour carter les risques d incendie de choc lectrique ou de blessure grave veiller toujours d brancher verrouiller et tiqueter la source de courant avant l installation...

Страница 20: ...d will match the models shown Install fuses per the manufacturer s recommendation Be sure to follow all national and local codes for electrical installation Fuse Sizing Chart VCFI 3 8 to 24 ft VCFI 6...

Страница 21: ...egulations and have experience with this type of equipment Once the fan has been put into operation a periodic maintenance program should be set up to ensure reliable fan performance A proper maintena...

Страница 22: ...nd fasteners for tightness Check guy wire tension if applicable Defective motor Replace motor Defective variable frequency drive VFD Replace VFD Fan does not operate Electrical supply Check for switch...

Страница 23: ...xxx 0 1000 RMS Modulated Output Voltage Volts 1 units 16 Current Motor RMS R xx x 0 150 RMS Motor current Amps 0 1 units 17 Temperature Motor R S xxx x 300 1100 Motor Temp C 0 1 units 18 Temperature T...

Страница 24: ...____________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _____...

Отзывы: