I-
tem 

 

Temperature class 

 

 

T6 = 85°C T5 = 100°C

T4 =135°C 

1. 

Permissible heating on the shaft 

30K 

45K 

65K 

2. 

Permissible heating on the flange 

30K 

45K 

65K 

 
 
 

 
 
Start-up 

 

 
 

 

 

 
 

Please note!  

Before mounting or start-up the insulation resistance is to be measured by qualified technicians. 
The resistance must be greater than 1 M

. A critical value is reached at 0.5 M

. If this value is not 

reached, the motors must be dried. 
 

 
 

 
 
The best way to do it is in an oven at temperatures up to 100 °C. To eliminate any humidity, open the motor. To be 
entitled to any warranty claims, contact the manufacturer in advance. 
 
These works must be carried out by qualified technicians; in the course of said works the manufacturer shall instruct 
said technicians on how to ensure the explosion protection during reassembly. For the assembly and disassembly, see 
the relevant repair instructions. 
 
•  Check the direction of rotation and operation during idle running. In case of unidirectional external fans (axial fans) 

observe the sign for the direction of rotation on the motor. If the direction of rotation needs to be changed, invert the 
two power lines and the fan. 

•  If the motor was stored and an additional quantity of grease was applied in the anti-friction bearings, the motor must 

be run with no load for at least 0.5 h to ensure an adequate distribution of the grease and to avoid the overheating of 
the anti-friction bearings. 

•  Make sure that the operating current matches the specified current values on the rating plate. 
 
  The protective equipment required as per EN 60079-14 is to be set according to the motor rating values specified on 

the rating plate. The specified current value on the rating plate must not be exceeded in continuous duty conditions. 

 

 

 

 

 
 

Please note!  

Run the motor with load for at least 1 hour and check that there is no unusual noise or heating ex-
ceeding the specified temperature class values. 
 

 

 
Relubricate motors with regreasing equipment with the specified amount of grease during start-up. 

Vibration severity values of V

eff

 

<

 3.5 mm/s (

P

N

 

<

15 kW) or 4.5 mm/s (

P

N

 > 15 kW) in coupled operating mode are 

not allowed. In case of deviations from normal operating conditions – e.g. higher temperatures or greater noise and 
vibrations – find the cause and, if necessary,  
contact Producent. 
 

 

 

 

 
 

Please note!  

The protective equipment must always be kept in service also during trial runs. In case of doubt 
switch off the machine. 
 

 
 
 

Maintenance

 

 
Inspection 

•  The motors are to be constantly monitored depending on the operating conditions. 
•  Keep the motors clean and the venting openings free 
 
Any national regulations valid for the maintenance/repair of electrical equipment in areas subject to explosion hazards - 
e.g. in Germany the Operational Safety Order, etc - are to be complied with.  
 
During maintenance especially those parts on which the degree of protection depends must be checked; these include, 
for instance, the integrity of the lead-in components and gaskets. 

 

Содержание KP Series

Страница 1: ...Operating and Maintenance Instruction Three Phase Asynchronous motors with squirrel cage version II2G EEx d e IIC T 3 6 VEM motors GmbH Ausgabe 07 2005 I...

Страница 2: ...bservation of following standards European Standard German Standard VDE Classification EN 50082 1 1997 DIN EN 50082 1 11 97 VDE 0839 82 1 11 97 EN 61000 6 4 2001 DIN EN 50081 2 03 94 VDE 0839 81 2 03...

Страница 3: ...to these guidelines it is important to adopt the necessary safety precautions to protect the personnel against possible injuries The personnel must be duly instructed to proceed with caution and accor...

Страница 4: ......

Страница 5: ......

Страница 6: ...the documents therein referred to 8 The Physikalisch Technische Bundesanstalt notified body No 0102 in accordance with Article 9 of the Council Directive 94 9 EC of 23 March 1994 certifies that this e...

Страница 7: ...t shall prevail Pysikalisch Technische Bundesanstalt Bundesallee 100 D 38116 Braunschweig 13 Schedule 14 EC TYPE EXAMINATION CERTIFICATE PTB 99 ATEX 1098 15 Description of equipment Three phase motors...

Страница 8: ...d Motors Intended use The motors are to be operated only according to the data specified on the rating plate According to the relevant marking on the rating plate the motors are fit for use in areas s...

Страница 9: ...f 70 and register changes in temperature greater than 10 C day In order to prevent damage during storage any occurring oscillations must amount to Veff 0 2 mm s For motors with regreasing systems repr...

Страница 10: ...risk being damaged during transportation Site The completely closed motors are intended for operating sites in which they are exposed to soiling humidity and other open air conditions as per the rele...

Страница 11: ...anti friction bearings Table 3 Minimum load on the shaft collar for motors with reinforced bearing Shaft height Minimum load Shaft height Minimum load Shaft height Minimum load 112 1100N 200 3400N 31...

Страница 12: ...on the shaft end plate and or on the rating plate H half key F full key N no key The design of the coupling or pulley must match the motor s balance Please note If balancing with half key H work on th...

Страница 13: ...N 60079 14 and EN 50281 1 2 Afterwards suitable overload protection is to be provided either with a motor circuit breaker or similar protective devices These may include also PTC thermistors with trip...

Страница 14: ...ed Anti corrosion protection can be achieved with non hardening sealing materials or sealing grease in particular on the processed sealing surfaces of the covers of terminal boxes having the following...

Страница 15: ...f is used for the insertion of lines in movable motors Please note Cable lead ins and sealing plugs that fail to meet these requirements are prohibited The cable and line diameters used must comply wi...

Страница 16: ...pplied wiring diagram Figure 8 Line connection Connection without cable lug Clamp Connection with cable lug Single wire conductor without cable lug When connecting a single wire conductor without cabl...

Страница 17: ...Thread size Torque Nm Permissible continuous current A Brass Copper M4 1 2 16 M5 2 25 M6 3 63 M8 6 100 M10 10 160 200 M12 15 5 250 315 M16 30 315 400 M20 52 400 630 Depending on the model additional t...

Страница 18: ...be protected by PTC temperature sensors rating data for this operating mode are specified either on the rating plate or on a separate plate If the rele vant plate is missing see the data provided in...

Страница 19: ...atter must be disassem bled Unscrew any shock pulse sensors or regreasing devices Loosen the fastening screws on the hood and remove the hood from the motor Connect the brake of tachometer as per the...

Страница 20: ...circuit Pole changing Low rpm High rpm Dahlander connection Low rpm High rpm Dahlander connection ow rpm High rpm L 1TP1 1TP2 Pre alarm PTC U 2 5V not allowed Use tripping device with PTB number or m...

Страница 21: ...rapid engagement of the brake DC voltage side tripping bridge 3 4 can be re placed by a contact The contact must be tripped simultaneously with the brake power supply circuit In order to provide for...

Страница 22: ...e of non S1 duty cycle motors proven combinations of TS and tripping device must be used as protection against overheating The supplying of power to the motors via the frequency converter is permissib...

Страница 23: ...the anti friction bearings Make sure that the operating current matches the specified current values on the rating plate The protective equipment required as per EN 60079 14 is to be set according to...

Страница 24: ...2500 h 50 C 2500 h 1000 h Please note In motors with enhanced performance motor type X in heavy drive conditions like belt and gear drive with additional bearing loads and in vertical designs the lubr...

Страница 25: ...pressure resistant encapsulation degree of protection marking EEx d IIC B All the screws are to be tightened to the envisaged torque and just as many screws as necessary for the envisaged fastening b...

Страница 26: ......

Страница 27: ......

Отзывы: