10 Function Code Instructions
233 SD780 Series Servo Technical Manual
Pn7A0
Encoder overflow
times
-32768
~
32767
0
N/A
0x07A0
Immediately
Record the number of times the multi turn absolute encoder overflows.
Pn7A1
Percentage of motor
locked rotor overload
protection time
0
~
100
8
N/A
0x07A1
After restart
This parameter sets the time percentage of motor overload after locked rotor. If the setting is too large,
the driver may be damaged. In order to protect the safety of the driver, please change this value under
the guidance of the manufacturer's technical support.
10.9 Pn8 Group Internal Position/Home Position Return Parameters
Function
code
Parameter
Range
Default
Unit
Communication
address
When
enabled
Pn800
Home position return
control word
0
~
0xFFFFFFFF
0x0
-
0x0800
Immediately
Home position return control word mode setting, see Chapter 8 for details.
Pn802
Zero position offset
value
-
2147483648
~
2147483647
0
command
unit
0x0802
Immediately
Set zero position offset position.
Pn804
Pr1 control word
0
~
0x80000000
0x0
-
0x0804
Immediately
Position setting of the first section,see Chapter 8 for details.
Pn806
Pr1 pulse number
-
2147483648
~
2147483647
0
command
unit
0x0806
Immediately
Set the position of the 1
st
segment.
Pn808
Pr2 control word
0
~
0x80000000
0x0
-
0x0808
Immediately
Same as Pn804.
Pn80A
Pr2 pulse number
-
2147483648
~
2147483647
0
command
unit
0x0810
After restart
Set the position of the 2
nd
segment.
Pn80C
Pr3 control word
0
~
0x80000000
0x0
-
0x080C
After restart
Same as Pn804.
Pn80E
Pr3 pulse number
-
2147483648
~
2147483647
0
command
unit
0x080E
Immediately