![Veichi SD780 Series Скачать руководство пользователя страница 234](http://html1.mh-extra.com/html/veichi/sd780-series/sd780-series_manual_3919156234.webp)
10 Function Code Instructions
228 SD780 Series Servo Technical Manual
Set the target torque reaching value.
Pn421
Target torque
reaching time
window
0
~
1000
5
ms
0x0422
Immediately
Set target torque reaching time window.
10.6 Pn5 JOG related parameters
Function
code
Parameter
Range
Default
Unit
Communication
address
When
enabled
Pn500
JOG speed
0
~
1000
500
rpm
0x0500
Immediately
Pn502
Program JOG
operation mode
0x00
~
0x05
0
-
0x0502
Immediately
0-(waiting time->forward running)*number of cycles.
1-(waiting time->backward running)*number of cycles.
2-(waiting time->forward running)*number of cycles->(waiting time->backward running)*number of
cycles.
3-(waiting time->backward running)*number of cycles->(waiting time->forward running)*number of
cycles.
4-(waiting time->forward running->waiting time->backward running)*number of cycles.
5-(waiting time->backward running->waiting time ->forward running)*number of cycles.
Pn503
Program JOG
running distance
1
~
1073741824
32768
command
unit
0x0503
Immediately
Set the JOG movement distance of the running program as the command unit.
Pn505
Program JOG
acceleration/
deceleration time
2
~
10000
100
ms
0x0505
Immediately
Set the time of accelerating from 0r/min to the rated speed (corresponding to the motor model). When
the set speed is greater or less than the rated speed, calculate the actual acceleration/deceleration
time according to the ratio.
Pn506
Program JOG
waiting time
0
~
10000
100
ms
0x0506
Immediately
Set the waiting time between JOG sections of the running program in conjunction with the program
JOG operation mode (Pn502).
Pn507
Program JOG
movement times
0
~
1000
1
circle
0x0507
Immediately
Set the movement times of the running program in conjunction with JOG operation mode (Pn502)
Note: it is infinite when set to 0.
Pn508
Program JOG
movement speed
1
~
10000
500
rpm
0x0508
Immediately
10.7 Pn6 Group Switch Configuration Related Parameters
Function
code
Parameter
Range
Default
Unit
Communication
address
When
enabled
Pn600
Switching value
input signal
distribution mode
0
~
1
1
-
0x0600
After restart