![Vega VEGABAR 82 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/vega/vegabar-82/vegabar-82_operating-instructions-manual_859602021.webp)
21
4 Mounting
VEGABAR 82 • Profibus PA
45031-EN-220624
1
4
3
2
1
2
3
4
Fig. 17: Measurement setup for the process pressure measurement of gases in
pipelines
1 VEGABAR 82
2 Blocking valve
3 Siphon in U or circular form
4 Pipeline
A protective accumulation of water is formed through condensation
in the pipe bends. Even in applications with hot steam, a medium
temperature < 100 °C on the transmitter is ensured.
Keep the following in mind when setting up the measuring system:
•
Mount the instrument below the measuring point
The effective pressure line is always filled with liquid and gas bubbles
can bubble up to the process line.
3
1
2
Fig. 18: Measurement setup for the process pressure measurement of liquids in
pipelines
1 VEGABAR 82
2 Blocking valve
3 Pipeline
Measurement setup in
liquids