a
Note: ARP
The ARP protocol only works within the same subnet as the IP address provided to the test set in IP
Status.
Go back to top
Go back to TOC
8.2 Net Wiz
The Net Wiz function allows you to test the Ethernet cable and associated network environment. A typical application is shown
below.
Net Wiz Test Application
Net Wiz test functionalities include:
Cable Analysis with distance
To switch with MDI mode (Straight or Crossover)
To fault, type of fault (Open, Short, Impedance Mismatch)
Analyze the network and automatically report
Stations
Routers/Gateway
Printers
Provide MAC and IP addresses of each device
PING each device and verify that the device is active
Provide detected networks (NetBiOS, IPX, etc)
Status
Press ‘Start’ to begin the test.
The test set will report the connection type (Straight or Crossover) if connected to an end point device.
If a fault is detected (Open or Short), the fault will be indicated, including the distance to the fault.
Discovery
Before proceeding with the discovery function, please go to IP Tools to establish a connection.
Enter the desired IP address range and press ‘Start’
Discovery Result:
Summary
tab reports:
Total transmitted and received frames
CX350 e-Manual D07-00-037 RevC01
Page 60 of 81
Содержание VePal CX350
Страница 1: ...CX350 e Manual D07 00 037 RevC01 Page 1 of 81...
Страница 5: ...CX350 e Manual D07 00 037 RevC01 Page 5 of 81...
Страница 13: ...Go back to top Go back to TOC CX350 e Manual D07 00 037 RevC01 Page 13 of 81...
Страница 16: ...Go back to top Go back to TOC CX350 e Manual D07 00 037 RevC01 Page 16 of 81...
Страница 21: ...Location Editor Location Editor Digital CX350 e Manual D07 00 037 RevC01 Page 21 of 81...
Страница 22: ...Go back to top Go back to TOC CX350 e Manual D07 00 037 RevC01 Page 22 of 81...
Страница 64: ...Go back to top Go back to TOC CX350 e Manual D07 00 037 RevC01 Page 64 of 81...
Страница 73: ...Go back to top Go back to TOC CX350 e Manual D07 00 037 RevC01 Page 73 of 81...