6.1 Setup
6.1.1 Port Setup
Port setup configuration is accessed from the Setup menu located on the home page of 10GE Test App.
UX400 10G Ethernet Test App Setup
The following configurations are available:
10G port profile
: Default
10GE Mode
: LAN / WAN
WIS Mode (for WAN):
SDH / SONET
Flow Control
: Enable
Clock Offset (ppm)
: Can be configured; range is +/- 150ppm
6.1.2 Measurement Setup
The measurement settings are configured on this screen.
Mode
: Manual, Timed
Manual mode: User manually starts and stops the measurements.
Timed mode: User defines the duration of the test; after the test is started, the test will run for the configured duration and stop automatically.
TX Start
: Separated and Coupled. Configure how the measurements are started when in BERT and Multiple Streams test modes.
Separated: Independent control (Start/Stop) of the transmitter is enabled. At the start of the test only the receiver is turned on -- the user must start the
transmitter manually.
Coupled: Transmitter and receiver are turned on at the same time, and the Tx and Rx measurements start at the same time at the start of the test.
Measurement Setup
UX400 10G e-Manual D07-00-058P RevA00
Page 38 of 209
Содержание UX400
Страница 1: ...UX400 10G e Manual D07 00 058P RevA00 Page 1 of 209 ...
Страница 33: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 33 of 209 ...
Страница 37: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 37 of 209 ...
Страница 142: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 142 of 209 ...
Страница 189: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 189 of 209 ...
Страница 203: ...DS1 RX Data Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 203 of 209 ...
Страница 205: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 205 of 209 ...