CHAPTER 3 - USER’S GUIDE
STAGE 1 DUTY CYCLE PERIOD
The stage 1 duty cycle period is adjusted in
conjunction with the stage 1 duty cycle timer
(primary function 2). The stage 1 duty cycle
period is the total time in ON-OFF fan cycle.
The period is adjusted by 1 minute increments
from a setting of 1 minute to a maximum
setting of 10 minutes.
Adjusting the stage 1 duty cycle period:
•
rotate the selector dial to position (12),
•
rapidly rotate the adjuster dial back and
forth to enter secondary function mode,
•
rotate the selector dial to position (2),
•
rotate the adjuster dial counterclockwise to
decrease the period, and clockwise to
increase it.
The stage 1 period setting is displayed on the
MST-5.
Period