2.4.2 Connecting to the actuator (figure 1)
•
Connect L1 to terminal L of the DIP-1/115.
•
Connect N (neutral) to terminal N of the DIP-1/115.
•
Connect a wire between terminal OPEN of the
DIP-1/115 and terminal OPEN of the actuator.
•
Connect a wire between terminal CLOSE of the
DIP-1/115 and terminal CLOSE of the actuator.
•
Connect a wire between terminal COM of the
DIP-1/115 and terminal COM of the actuator.
•
Connect a shielded cable between terminal (wiper) of
the potentiometer and terminal (POT) of the DIP-1/115.
•
Connect a shielded cable between the potentiometer
and terminal (GNA) of the DIP-1/115.
•
Verify jumpers according potentiometer used (figure 3).
The accuracy of the actuator’s positioning depends on the
type of actuator. The positioning is accurate at more or
less 1/8 in (3mm)
2.4.3 Connecting to the ECS-M
•
Disconnect power of the ECS-M.
•
These cables can extend up to a distance of 6 feet (2
meters).
•
Connect one end of the cable to the (SIN), (SCK) and
(GND) terminal of the DIP-1/115 to the ECS-M. (If you
connect only one unit to the DIP-1/115, use terminal
(AUX INPUT 1).
CHAPTER 2 - INSTALLATION
NOTE
It is recommended to use the actuator on the longest
travel time possible to obtain maximum accuracy in
the curtain’s positioning (min. 12 in. or 30 cm).
Remember that a bad connection of the cables / pulley
between the actuator and the curtain influences the
accuracy of the curtain’s positioning.
www.monitrol.com
Содержание DIP-1/115
Страница 6: ...Page 6 DIP 1 115 www monitrol com ...
Страница 45: ...Page 45 APPENDIX www monitrol com ...
Страница 46: ...Page 46 DIP 1 115 www monitrol com ...
Страница 48: ...Page 48 DIP 1 115 www monitrol com ...
Страница 52: ...MAV DIP 1 115 Ver 0 1 June 22 2005 version 016 www monitrol com ...