Page 14
DIP-1/115
CHAPTER 3 - USER’S GUIDE
The DIP-1/115 front panel shown next features a LED
status window and two control dials that are respectively
used to select a function and adjust a setting.
LED STATUS WINDOW
The LED status window features a 3 digit LED readout for
outside temperature, the display of inlet position and
programmable settings.
In addition, the LED status window displays the operational
status of air inlet, control, potentiometer and alarm via 6
additional LEDS (shown next in LED window). The first
and second LEDs indicate if the air inlet is closing or
opening. The third LED indicate the DIP-1/115 in manual
mode. The fourth LED provides the potentiometer actual
status: if the LED flashes when the actuator is ON, this
means the DIP-1/115 detect an intermittent contact coming
from the potentiometer. Solution: replace the
potentiometer. If the LED flashes while the actuator is
stopped, this means the DIP-1/115 do not detect the
presence of the potentiometer. Solution: verify the wiring
and the potentiometer. The fifth LED indicates when the
auto-calibration is in process, and the sixth indicate an
alarm to lost contact between ECS-M and DIP-1/115.
CONTROL DIALS
The center dial is the Selector dial and is used to select
one of the DIP-1/115’s 12 primary or secondary functions.
The dial located to the right of the Selector is the Adjustor
dial and is used to enter secondary function mode and to
adjust setting of each function.
www.monitrol.com
Содержание DIP-1/115
Страница 6: ...Page 6 DIP 1 115 www monitrol com ...
Страница 45: ...Page 45 APPENDIX www monitrol com ...
Страница 46: ...Page 46 DIP 1 115 www monitrol com ...
Страница 48: ...Page 48 DIP 1 115 www monitrol com ...
Страница 52: ...MAV DIP 1 115 Ver 0 1 June 22 2005 version 016 www monitrol com ...