Page 27
POSITION FOR THE THIRD STAGE (UNIT 1)
The position for the third stage (unit 1) sets the
air inlet position when the third stage (unit 1)
begins to operate.
Adjusting the position for the third stage
(unit 1):
•
rotate the Selector dial to position (7),
•
rotate the Adjustor dial counterclockwise to
decrease the end position for the third
stage (unit 1),and clockwise to increase it.
The position for the third stage (unit 1) is
displayed on the DIP-1/115 is adjusted in
opening percentage (0-100%).
Example: The position for the third stage is set to 79%.
When the third stage (unit 1) begins to operate the air
inlet opens at 79%.
CHAPTER 3 - USER’S GUIDE
www.monitrol.com