background image

 

 

Request for Return 

 

 

 

1.  A Return Authorization Number (RA#) 

WILL NOT

 be issued until this Request for Return is completely filled out, 

signed and returned to Varian Customer Service. 

2.  Return shipments shall be made in compliance with local and international 

Shipping Regulations

 (IATA, DOT, UN). 

3.  The customer is expected to take the following actions to ensure the 

Safety

 of workers at Varian

:

 (a) Drain any oils or 

other liquids, (b) Purge or flush all gasses, (c) Wipe off any excess residues in or on the equipment, (d) Package the 
equipment to prevent shipping damage, (for Advance Exchanges please use packing material from replacement unit). 

4.  Make sure the shipping documents clearly show the RA# and then return the package to the Varian location nearest you.   

North and South America 

Varian Vacuum Technologies 

121 Hartwell Ave 

Lexington, MA 02421 

Phone : +1 781 8617200 

Fax: +1 781 8609252 

Europe and Middle East 

Varian SpA 

Via Flli Varian 54 

10040 Leini (TO) – ITALY 

Phone: +39 011 9979111 

Fax: +39 011 9979330 

Asia and ROW 

Varian Vacuum Technologies 

Local Office 

 

CUSTOMER INFORMATION 

 

Company name: ..………………….……..……………….………………………………..……………………...…………..…. 
Contact person:    Name: ……………………………………..… 

Tel: ……………………….…...…………….….….... 

  

Fax: …………………………….…...…..…… 

E-Mail: ..……………………..…………..…..…..….. 

Ship Method: …………….……....…… Shipping Collect #: ………….…..………… P.O.#: ………………….…......……….. 

Europe only

:   VAT reg. Number: ………………..……………... 

USA only:

   

 

Taxable     

 

Non-taxable  

Customer Ship To: ………………………….………   

Customer Bill To: …………………..……………... 

                 ……………..…………………...                                

 ..………………………………... 

                 ………………..………………...                                 

 ..………………………………...                      

 

PRODUCT IDENTIFICATION 

Product Description 

Varian P/N 

Varian S/N 

Purchase Reference 

 

 

 

 

 

 

 

 

 

 

 

 

 

TYPE OF RETURN 

(check appropriate box)

 

 

 

 

 

 

Paid Exchange      

 

Paid Repair 

 

Warranty Exchange 

 

Warranty Repair 

 

Loaner Return 

 

Credit  

      

 

Shipping Error 

 

Evaluation Return 

 

Calibration  

 

Other ……………….

 

 

HEALTH and SAFETY CERTIFICATION 

Varian Vacuum Technologies 

CAN NOT ACCEPT

 any equipment which contains 

BIOLOGICAL HAZARDS

 or 

RADIOACTIVITY

. Call Varian Customer Service to discuss alternatives if this requirement presents a problem. 

The equipment listed above (check one): 
    

 

HAS NOT

 been exposed to any toxic or hazardous materials 

       OR 

    

 

HAS

 been exposed to any toxic or hazardous materials. In case of this selection, check boxes for any materials that      

equipment was exposed to, check all categories that apply: 

  Toxic        Corrosive        Reactive        Flammable        Explosive        Biological        Radioactive 

List all toxic or hazardous materials. Include product name, chemical name and chemical symbol or formula. 

.……………………………………………………………………………………………………………………..

 

 

Print Name: ………………………………….      Customer Authorized Signature: ……………...…………………….     

Print Title: …………………………………...      Date: ..…../..…../……  

NOTE:

 If a product is received at Varian which is contaminated with a toxic or hazardous material that was not disclosed, 

the customer 

will be held responsible

 for all costs incurred to ensure the safe handling of the product, and 

is liable

 for any harm or injury to Varian 

employees as well as to any third party occurring as a result of exposure to toxic or hazardous materials present in the product. 

 

Do not write below this line 
Notification (RA)#: ……………………….………..  Customer ID#: ……….………….  Equipment #: …………………….. 

Содержание Turbo-V70

Страница 1: ...87 900 879 01 A APRIL 2002 INSTRUCTION MANUAL Turbo V70 controller Eurocard Model 969 9514 vacuum technologies...

Страница 2: ...utline 3 II Installation 2 1 General 4 2 2 J2 connector 4 2 3 J3 connector 4 2 4 J4 connector 4 2 5 J5 RS 232 interface connector 4 2 6 RS 232 communication description 5 III Operation 3 1 General 7 3...

Страница 3: ......

Страница 4: ......

Страница 5: ...operation maintenance manuals and any additional information provided by Varian All warnings and cautions should be read carefully and strictly observed Address any safety operation and or maintenance...

Страница 6: ...ncy converter which is driven by a single chip microcomputer and is composed of a PCB which includes all the circuitry necessary for its operation The microcomputer generates the variable output volta...

Страница 7: ...SECTION I DESCRIPTION 87 900 879 01 A 3 1 4 Controller outline The outline dimension for the controller are shown in Fig 1 1 Figure 1 1 Controller outline...

Страница 8: ...the following Pin 3 Failure When a fault condition is detected the pump is stopped and a signal is present on this pin Pin 5 Low Speed mode activated When the Low Speed mode is activated a signal is p...

Страница 9: ...ter reading request 06 parameter writing Data in this controller it can be in the case of parameter reading request 000000 or 111111 in the case of YES NO command or parameter writing a six numeric ch...

Страница 10: ...l to 1 can be only read equal to 1 can be only written PARAMETER NUMBER TYPE DESCRIPTION X0002 D Low speed ON OFF X0003 D Pump ON OFF X0008 D Remote ON OFF 10009 D Error acknowledgment error status cl...

Страница 11: ...the same connector To switch off the pump is necessary to connect pin 12 of J4 connector to pin IS ground of the same connector 3 3 Low speed activation deactivation To activate the Low Speed status...

Страница 12: ...signals the error occurred by means of a diagnostic LED located on the board and on the RS 232 port The LED blinks in a coded mode it flashes a number of time equal to the error code see the following...

Страница 13: ...TIFICATION Product Description Varian P N Varian S N Purchase Reference TYPE OF RETURN check appropriate box Paid Exchange Paid Repair Warranty Exchange Warranty Repair Loaner Return Credit Shipping E...

Страница 14: ...rate No zero high backround Gauge tube not working Display problem Vacuum system unstable Cannot reach test mode Communication failure Degas not working Failed to start Other Error code on display Oth...

Страница 15: ...an India PVT LTD 101 108 1st Floor 1010 Competent House 7 Nangal Raya Business Centre New Delhi 110 046 India Tel 91 11 5548444 Fax 91 11 5548445 Italy Varian Vacuum Technologies Via F lli Varian 54 1...