2
02.9676.0022 0
09-December-2004
23
Beam Spreader Motor Assembly Replacement
Parts:
22.9671.0468
ASSY, BEAM SPREADER MOTOR ASSY
To remove and replace beam spreader motor assembly:
WARNING:
All maintenance procedures are to be performed with power removed
from the luminaire.
Step 1. Disconnect luminaire AC input cable from power source.
Step 2. Remove front internal head assembly. Refer to
“Front Assembly Removal”
on page 22
.
Step 3. Disconnect beam spreader motor assembly wire connector from motor
harness cable assembly.
Step 4. Remove two 4-40 KEPS nuts securing motor assembly to bulkhead.
Step 5. At beam spreader motor assembly, using 1/4" open-ended wrench and pliers,
remove one 4-40 KEPS nut from end of motor shaft (
Figure 2-8
).
Step 6. Slide motor forward to clear bulkhead and remove.
Step 7. Install new motor assembly following Steps 2 through 6 in reverse order.
Figure 2-8: Beam Spreader Motor Assembly Replacement
Beam Spreader
4-40 KEPS Nut
4-40 KEPS Nut (2)
Motor Assembly
Содержание VL2500 Spot Luminaire