Wear cotton gloves or other covering while servicing lamp. Touching lamp
glass with bare fingers will leave oil and may cause the lamp to explode or reduce
lamp life. If required, use alcohol and cotton cloth to thoroughly clean glass portion of
lamp.
Step 4. Remove lamp by pulling straight out of socket.
Step 5. Install new lamp by pressing into socket. Ensure lamp is fully seated in
socket and parallel to guide rods. (Lamp can be damaged when inserted
through reflector if not parallel to guide rods.)
Step 6. Align guide rods in guide holes and slide backcap into head assembly. Re-
tighten captive knob.
Step 7. If required, reset lamp hour counter as follows. (Refer to "Menu System" in
VL2500 Wash Luminaire User’s Manual for more information.)
a. Power up luminaire.
b. At Menu Display, press [Menu].
c. Press [Up] / [Down] arrows until
Config
(Configuration) appears. Press
[Enter].
d. Press [Up] / [Down] arrows until
Lamp
appears. Press [Enter].
e. Press [Up] / [Down] arrows to access
ResetHrs
. Press [Enter] to reset
lamp hour and strike counters.
f. Align lamp.
See “Align Lamp for Flat Field” on page 18..
Figure 2-2: Lamp Alignment
Vertical
Horizontal
Focus
Captive Knob for lamp access
(does not adjust beam)
Содержание VL2500 Spot Luminaire
Страница 1: ......
Страница 18: ...VARI LITE VL2500 WASH LUMINAIRE SERVICE MANUAL xviii 09 December 2004 02 9676 0022 0 Notes...
Страница 124: ...VARI LITE VL2500 WASH LUMINAIRE SERVICE MANUAL 106 09 December 2004 02 9676 0022 0 Notes...
Страница 148: ...VARI LITE VL2500 WASH LUMINAIRE SERVICE MANUAL 130 09 December 2004 02 9676 0022 0 Notes...
Страница 167: ......