Specifications
Tank Gauge Transmitter
32
Installation and Operations Manual
5.1.4
Level Measurement
Item
Description
Resolution
0.04 in (1.0 mm)
Counter Level Range
+/-128 ft (39 M)
Count Verification
Check Disk
Level Data Type
Absolute with Calibrated Level
Calibration Level
Software Configured
Units of Measure
Software Configured
Direction of Rotation
Software Configured
Rotational Speed
1000 RPM Maximum
Gear Ratio
1:1 - No Gears
Communications Check
Depends on communication system
Count Error Status
Flag to System
Battery Low Status
Flag to System
Battery Operation
336 Hours (with automatic shut-off after 24)
Battery Shelf Life
10 Years