high performance crane special inverter User Manual
Chapter 5 Debugging process 33
◆
Display of running and stop parameters
● In the running and stop state, 4 parameters are displayed by default, and the parameters are switched
by the >> key.
● In the running state, the monitoring of the required parameters can be selected through P2.02. Each of
the ones, tens, hundreds, and thousands can be monitored by one parameter. A total of four parameters
can be monitored, and the >> key can be used to switch.
● Each ones, tens, hundreds, and thousands can be selected from 0 to F, and 0 to F represent 16
monitorable parameters:
0: given frequency (Hz);
;
1: bus voltage (V);
2
:
AI1
(
V
);
3
:
AI2
(
V
);
4
:
AI3
(
V
);
5
:
DI
(
%
);
6: external count;
7: motor speed (rpm);
8: encoder feedback
frequency (/);
9: encoder feedback
motor speed;
;
A: given torque (%);
B: operating frequency
(Hz);
C: output current (A);
D: output torque (%);
E: output power (kW);
F: output voltage (V);
● In the state of shutdown, the monitoring of the required parameters can be selected through P2.02.
Each of the ones, tens, hundreds, and thousands can be monitored by one parameter. A total of four
parameters can be monitored, and the >> key can be used to switch.The parameters that can be
monitored are described in the same table above.
◆
Monitoring of other parameters
● d2.00
:
Radiator temperature
● d2.09: X terminal input status display, 0 means disconnected, 1 means closed, hexadecimal
combination, lowest digit means X1
D2.09 ones: represent X1 ~ X4 state, d2.09 tens: display X5 ~ X7 state.
As shown in the figure below, 0 means invalid and 1 means valid:
Single digit
display
X4
X3
X2
X1
Ten-digit
display
X7
X6
X5
0
0
0
0
0
0
0
0
0
1
0
0
0
1
1
0
0
1
2
0
0
1
0
2
0
1
0
3
0
0
1
1
3
0
1
1
4
0
1
0
0
4
1
0
0
5
0
1
0
1
5
1
0
1
6
0
1
1
0
6
1
1
0
7
0
1
1
1
7
1
1
1
8
1
0
0
0
9
1
0
0
1
A
1
0
1
0
b
1
0
1
1
C
1
1
0
0
D
1
1
0
1
E
1
1
1
0
F
1
1
1
1