high performance crane special inverter User Manual
Chapter 4 Crane special inverter parameters lists 17
Function
code
number
Function code name
Factory
setting Setting range
Unit Property
Function code selection
E: Output power (kW);
F: Output voltage (V);
Tens, hundreds, thousands place:
Same with above
P2.03 Display parameter selection
at stopping
3210
0
~
FFFF
/
○
Ones place:
0: Reference frequency (Hz)
1: Bus voltage (V)
2: AI1(V)
3: AI2(V)
4: AI3(V) 5~F: Reserved
Tens, hundreds, thousands place:
Same with above
Group P3 Start/stop Parameters
P3.00
Startup mode
0
0
~
1
/
×
0: Normal startup
1: Start after DC injection
P3.02
DC injection time
0.0
0.00
~
300.0
s
×
Injection current is set to P3.07
P3.03
Startup frequency
0.00
0.50
0.00
~
60.00
Hz
×
Encoder speed control defaults to 0.00, other
controls default to 0.50
P3.04 Startup frequency retention
time
0.0
0.0
~
3600.0
s
×
0.0
~
3600.0s
P3.05
Stop mode
0
0
~
1
/
×
0: Deceleration to stop, if P3.08≠0, DC brake after
deceleration stop
1: Coast to stop
P3.06 DC braking initial frequency
0.00
0.00
~
300.00
Hz
×
f P3.08=0, stop after decelerating to 0 frequency;
If P3.08≠0, decelerate to the frequency set by
P3.06 and then enter DC braking, the DC braking
current is set to P3.07, and it will stop completely
after the time set by P3.08.
P3.07
DC braking current
0.0
0.0
~
120.0
%
×
P3.08
DC braking time
0.0
0.00
~
300.0
s
×
P3.09
Anti−reverse selection
0
0
~
1
/
×
0: Run reverse is enabled
1: Run reverse is disabled
P3.10
Forward / reverse dead
zone time
0.0
0.0
~
3600.0
s
×
0.0
~
3600.0s
P3.11
Forward and reverse
switching frequency
2.00
0.00~300.00
Hz
Group P4 Multi−step Parameters
P4.00
V/F curve reference
0
0
~
6
/
×
0: Direct line
1: Multi−step (P4.01 ~ P4.08)
2~6: Reserved
P4.01
V/F frequency F0
0.00
0.00
~
300.00
Hz
×
F0<F1
P4.02
V/F voltage value V0
0.0
0.0
~
100.0
%
×
0.0
~
100.0%
P4.03
V/F frequency F1
0.00
0.00
~
300.00
Hz
×
F1<F2
P4.04
V/F voltage value V1
0.0
0.0
~
100.0
%
×
0.0
~
100.0%
P4.05
V/F frequency F2
0.00
0.00
~
300.00
Hz
×
F2<F3
P4.06
V/F voltage value V2
0.0
0.0
~
100.0
%
×
0.0
~
100.0%
P4.07
V/F frequency F3
0.00
0.00
~
300.00
Hz
×
P0.15 F3≤Motor basic frequency P0.15
P4.08
V/F voltage value V3
0.0
0.0
~
100.0
%
×
0.0
~
100.0%