high performance crane special inverter User Manual
Chapter 4 Crane special inverter parameters lists 15
Chapter 4 Crane special inverter parameters lists
Meaning of each item in function code parameter table:
Item
meaning
Function code
The number of function code, such as P0.00
Function code name
The name of function code, which explains the function code
’
s meanings.
Factory setting
Restore the settings of the function code after the inverter is delivered (see P0.01).
Setting range
The value from minimum value to maximum value that can be set to this function code.
Unit
V: Voltage; A: Current;
º
C: Celsius degree;
Ω
: Ohm; mH: Milli
−
henry; rpm: Rotating speed; %:
Percentage; bps: baud rate; Hz, kHz: Frequency; ms, s, min, h, kh: Time; kW: Power; /: No unit
Property
○
: This function code can be changed during operation;
×
: This function code can only be
changed during stopping process; *: The setting of this function code is read
−
only and cannot be
changed.
Function code
selection
Function code parameter setting list
Function
code
number
Function code name
Factory
setting Setting range
Unit Property
Function code selection
Group P0 Basic Function Parameter
P0.00 User password
0000
0
~
FFFF
/
○
0
:
No password;
Other: Password protection
P0.01 Function code
protection
0
0
~
5
/
×
0: All the parameters can be modified;
1: All the parameters cannot be modified;
2: Restore parameters in zone P to factory settings;
3: Restore parameters in zone P to factory settings;
(except for P9 group)
4: Recover the parameters in zone P and zone A to
factory settings;
5: Recover all the parameters to factory settings.
(except for d group)
P0.02 Function code
display
0
0
~
3
/
○
0: Basic menu mode
1: Fast menu mode
2: Menu mode of non-leave-factory setting value
function codes;
3: Menu mode of last changed 10 function codes;
P0.03 Control operation
mode
0
0
~
11
/
×
0: no encoder feedback vector control 1;
4: no encoder feedback vector control 2;
8: There is encoder feedback vector control 2; (only
V6 series is valid)
P0.04 Open loop main
reference mode
00
00
~
FF
/
○
Ones place:
0: Open loop digital frequency reference mode
1: AI1 analog value reference mode
2: AI2 analog value reference mode
3: AI3 analog value reference mode
Tens palce: reserved
P0.05
Open loop digital frequency
reference
10.00
0.00
~
300.00
Hz
○
P0.04=0 and the frequency given in the case when
the multi-segment frequency terminal is invalid
P0.06 Running command
reference mode
0
0
~
2
/
○
0: Operation panel 1: Terminal
2: Communication