high performance crane special inverter User Manual
10
Chapter 2 Installation and Wiring of the Inverte
2.3 Control loop wiring
Type
Terminal
symbol
Terminal function
description
Technical specification
7 digital inputs
+24V
+24V
24V±10%, internal isolated with GND
Maximum output current: 200mA, with overload and
short circuit protection
PLC
Common terminal of the
input terminal
Short circuited with +24V by default
COM
Ground terminal for
+24V
Internal isolated with GND
X1
~
X6
Multi−function input
terminals 1 ~ 6
Input specification: 24VDC,5mA
Frequency range: 0 ~ 200Hz
Voltage range: 24V±20%
X7/DI
Multi−function input or
pulse input
Multi−function input: same as X1 ~ X6
Pulse input: 0.1kHz ~ 50kHz
Voltage range: 24V±20%
3 output
terminals (2
open
collectors and
1 relay)
Y1
Open collector output
Voltage range: 24V±20%, maximum input current: 50mA
Y2/DO
Open collector or pulse
output
Open collector: same as Y1
Pulse output frequency: 0 ~ 50kHz
Pulse output voltage range: 24V±20%
COM
Open collector output
common end
Internal isolated with GND
RA/RB/RC
Relay output
RA−RB: normally closed
RA−RC: normally open
Contact capacity: 250VAC/1A, 30VDC/1A
3 Analog
input
+10V
Analog input reference
voltage
10V ±3%, internal isolated with COM
Maximum output current: 10mA, with short circuit and
overload protection
﹡
GND
Analog ground terminal
Internal isolated with GND
AI1
Analog input channel 1
0~20mA: input impedance 500Ω
maximum input current: 30mA
0~10V: input impedance 20kΩ
maximum input voltage: 15V
Resolution: 12 bits (0.025%)
0 ~ 20mA or 0 ~ 10V analog input can be selected by
jumper
4 ~ 20mA or 2 ~ 10V analog input can be changed by
parameters
AI2
Analog input channel 2
Same as AI1
AI3
Analog input channel 3
−10V ~ 10V: input impedance 20kΩ
Resolution: 12 bits (0.025%)
Maximum input voltage: ±15V
2 Analog
output
AO1
Analog output 1
0 ~ 20mA: allowable output impedance 200 ~ 500Ω
0 ~ 10V: allowable output impedance ≥10kΩ
Output precision: 2%
Resolution: 10 bits (0.1%), with short circuit protection
0 ~ 20mA or 0 ~ 10V output can be selected by jumper
4 ~ 20mA or 2 ~ 10V analog output can be changed by
parameters
AO2
Analog output 2
Same as AO1
GND
Analog ground terminal
Internal isolated with COM
Содержание V5 Series
Страница 10: ......