106 bright blue Installation Manual
•
NC is Normally Closed
•
C is Common
•
NO is Normally Open
The VBB-NRI G2 has four unsupervised contact points. Unsupervised door contacts have maximum wire length of
2,000 feet.
5 Contact Inputs 1 & 2
•
1 is Exit Request (REX)
– N/O
•
2 is Door Position Switch (DOD)
– N/C
•
C is Ground
6 Contact Inputs 3 & 4
•
3 is Push Button Override
– N/O
•
4 is Auxiliary Input
– N/C
•
C is Ground
7 & 9 Read Head Connection
▪
1 is LED
▪
2 is Not Used
▪
C is Not Used
▪
A is CLK (Data 0)
▪
B is DAT (Data 1)
▪
- is Ground
▪
+ is Power
8 & 10 Not Used
11 Not Used
19 Not Used
20 Not Used
21 Not Used
22 Not Used
23 Read Head Voltage Selector. The VBB-NRI G2 read head voltage selector provides wither 12 VDC or passes
VIN to the read head depending on jumper location.
▪
A jumper across PINs 2 and 3 (12V) will provide 12 VDC (default setting)
▪
A jumper across PINs 1 (Vin) and 2 will pass VIN
▪
No jumper will provide 0 VDC
Warning:
Serious damage may occur to the read-head if this jumper is set incorrectly. Please check the read
head voltage requirements.
16 Configure network functionality.
Refer to Configure GUI section above.