AIR N ARC
®
300 SERIES ALL-IN-ONE POWER SYSTEM
®
SECTION 5: OPERATION
090010-OP_r0
PAGE - 53
2. Turn the Generator switch on the control
panel to the
ON
position.
Combined output on all generator receptacles is limited
to the total rated generator capacity. For example; if
1,500 watts (12.5 amps) is being drawn on the 120V
duplex receptacle, only 3,700 watts (15.5 amps) is
available at the 240V receptacle. Reference
Appendix
A, Section A.3, Wattage Requirements for Common
Receptacle Units
,
for general information on the power
requirements of common power tools, motors and
extension cords. If the equipment is not listed in
Section
A.3
, check the desired power tool, motor or extension
cord manufacturer’s specifications.
If the thermal overload circuit breakers on the generator
are tripped due to an overload condition, press the white
reset buttons on the generator panel to reset the
breakers (
Figure 5-4
).
5.6 OPERATING THE AIR
COMPRESSOR
The air compressor and the supply of high pressure air
can be turned off. Whenever the pressure in the air tank
drops below 150 psi or the set pressure, the engine will
run at high speed until the pressure in the tank reaches
175 psi or set pressure. the pressure gauge on the panel
displays the current tank pressure.
NOTE
Only plug power cords into the generator
receptacles AFTER the engine is running
at full speed.
NOTE
Be careful not to overload the rated
capacity of the generator - 6,800 watts
(28 amps @ 240V) continuous.
WARNING
If one of the generator circuit breakers is
tripped, the cause of the overload must
be determined before the circuit breaker
is reset and work is resumed.
Figure 5-4: Resettable Circuit Breakers
NOTE
The Air N Arc 300 Power System unit
features a high pressure, 175 psi air
system. Check the maximum air
pressure rating on the air tools being
used. The operator is responsible for
regulating the air pressure when
necessary (See
Section 6.5.15, Adjusting
the Pressure Setting
).
Содержание Air N Arc All-in-One Power Systems 300
Страница 10: ...TABLE OF CONTENTS AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE VIII P01080 003 BLANK PAGE...
Страница 14: ...GLOSSARY AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE XII 090010 OP_r0 BLANK PAGE...
Страница 50: ...SECTION 2 DESCRIPTION AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 32 090010 OP_r0 BLANK PAGE...
Страница 54: ...SECTION 3 SPECIFICATIONS AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 36 090010 OP_r0 BLANK PAGE...
Страница 74: ...SECTION 5 OPERATION AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 56 090010 OP_r0 BLANK PAGE...
Страница 134: ...SECTION 8 DIAGRAMS AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 116 090010 OP_r0 BLANK PAGE...
Страница 137: ...AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM SECTION 9 ILLUSTRATED PARTS LIST 090010 OP_r0 PAGE 119 NOTES...
Страница 174: ...SECTION 9 ILLUSTRATED PARTS LIST AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 156 090010 OP_r0 BLANK PAGE...
Страница 182: ...APPENDIX A ADDITIONAL INFORMATION AIR N ARC 300 ALL IN ONE POWER SYSTEM PAGE 164 090010 OP_r0 BLANK PAGE...
Страница 198: ...APPENDIX B INSTRUMENT PANEL FUNCTIONS AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 180 090010 OP_r0 BLANK PAGE...
Страница 202: ...APPENDIX C MAINTENANCE AND SERVICE LOG AIR N ARC 200 SERIES ALL IN ONE POWER SYSTEM PAGE 184 090010 OP_r0 BLANK PAGE...