V-460/610 Series Operating Instructions Ver.2.04E
50
[Replace when] When the center-dry tape is breaks,
burns, or when the seal becomes
messy, etc.
[Essential tools] Scissors, flathead screwdriver
Replace the center-dry tape adhered to the pressure
lever (upper lever) to the new one.
1
Lift up the frame cover.
2
As in the right illustration, remove E-rings
using a flathead screwdriver as well as the pins.
3
Now you can lift the pressure lever to push it
over to the other side. Remove a sponge rubber
from the holder.
4
Remove the damaged center-dry tape.
As in the right illustration, insert the edge of
new center-dry tape between the pressure lever
and sponge holder. Adhesive side of the center-
dry tape must face toward the pressure lever.
Adhere one side of center-dry tape’s adhesive
part to the pressure lever.
9-2 Replacing the center-dry tape on the
upper lever (for double-side heating
models)
Pressure lever
Sponge rubber
E ring
Pin
Flathead screwdriver
Attention
The center-dry tape may get vertical
line as sealing repeatedly, but it does
not affect seal result.
Attention
When it is hard to adhere the center-dry tape
to the pressure lever, use a thin plate such as
a ruler and slide it between the pressure lever
and sponge holder so the adhesive part of
center-dry tape adheres to the pressure lever.
Содержание V-460 Series
Страница 61: ...V 460 610 Series Operating Instructions Ver 2 04E 61 ...
Страница 66: ...V 460 610 Series Operating Instructions Ver 2 04E 66 12 Electric diagram 110V ...
Страница 67: ...V 460 610 Series Operating Instructions Ver 2 04E 67 220V ...
Страница 68: ...V 460 610 Series Operating Instructions Ver 2 04E 68 13 Piping diagram V 460 610 series ...
Страница 69: ...V 460 610 Series Operating Instructions Ver 2 04E 69 V 460 610C series ...
Страница 75: ...V 460 610 Series Operating Instructions Ver 2 04E 75 ...