© Valco Cincinnati, Inc.| 411 Circle Freeway Dr.| Cincinnati, OH 45246 | USA
www.valcomelton.com | TEL: (1) 513-874-6550 | FAX: (1) 513-874-3612
Doc. IS0xxx
Rev.04 | Date: August 25, 2021
MCP-8I Quick Start Guide
Window Display Graphics
·
Global Jam Setting Input Box
– is used to set the Jam Distance for all Jam Channels
at the same time.
Note –
Each Channel still has to be Enabled and Disabled. Once the
Desired Channels are Enabled, the Global Jam Setting will be transferred.
Figure 10: Jam Global Setting Input Box
·
Jam Option Text Descriptions
o
Valve Channel Jam
§
‘V’ – Indicates Valve Channel
§
1 – Indicates the Valve Index
§
‘Scanner 1’ – Indicates the Scanner/Trigger Input Selection.
Figure 11: Valve Jam Prompt
o
Sensor Channel Jam
§
‘S’ – Indicates Sensor Channel
§
‘1’ – Indicates the Sensor Index
§
‘Int 1’ – Indicates the Scanner/Trigger Input Selection.
Int 1 = Scanner that is connected to Sensor 1 Sensor.
Figure 12: Sensor Jam Prompt
o
Sync Scanner Jam
Figure 13: Sync Scanner Jam Prompt
Note –
This will only be present when the Sync Scanner is Enabled and the
External Learn is Disabled.