© Valco Cincinnati, Inc.| 411 Circle Freeway Dr.| Cincinnati, OH 45246 | USA
www.valcomelton.com | TEL: (1) 513-874-6550 | FAX: (1) 513-874-3612
Doc. IS0xxx
Rev.04 | Date: August 25, 2021
MCP-8I Quick Start Guide
How to Determine the Sensor’s Signal ‘Delta / Range / Amplitude’
1. Navigate to the
‘Inspection Window’
by pressing the button labeled ‘
INSPECT
’.
Figure 105: Navigating to the Inspection Window
2.
Navigate to the ’
Inspection Diagnostic’s Window
‘ by pressing the ’
DIAGN
‘ button.
Figure 106: Navigating to the Inspection Diagnostic Window
3.
Jog an ’
Unglued Product
‘ up to the sensor and
stop with the product underneath
the sensor
.
4.
When the belts are
stopped
, the ’
Information Bar’s
‘ description changes to display
the text ’
Current
‘. The number next to the text is the sensor’s ’
Current Value
‘. Record
this number as the ’
Low Point
‘.
Figure 107: Current Sensor Value For Product Without Glue