MUS033202
18/10/2010
VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA
TEL: +34 948 321580 Fax: +34 948 326584 [email protected] www.valcomelton.com
54
7.3. ELECTRICAL FAULTS:
Differential on the card that
supplies energy to the gluer
trips
Check electrical leakage in
applicator resistance and
peripherals
Check that the differential is
the right one for the power
requirement of the gluer
The machine does not come on
Check the connection of the
power supply to the
machine
Check the power fuses of the
electronic card
The machine comes on but is
not enabled
Check correct programming
and parameterising of the
machine
Check safety thermostat
The tank overheats
Check the temperature
sensor in the tank
Check if the triac of the
tank is short-circuited
Check that the electronic
card works properly
Check the programmed
temperature of the tank