MUS033202
18/10/2010
VALCO MELTON S.L.U. Pol. Ind. Agustinos C/G 34 3116 0 ORCOYEN, NAVARRA
TEL: +34 948 321580 Fax: +34 948 326584 [email protected] www.valcomelton.com
43
Bleed Process:
The bleed process is done to sweep away small crystallisations that
may be produced in the filter and if you wish to depressurise the
system.
Before purging the filter, put on goggles, gloves and long-sleeve shirt to
prevent possible burns caused by hot adhesive splashing.
1º
To purge the filter, the applicator must be at the operating
temperature.
2º
Reduce the air pressure of the applicator to “0”.
3º
Place a container below the equipment to collect the adhesive in
the distributor.
4º
Open the bleed valve with a screw driver.
Tip:
Bleed
the
equipment once
a week or every
40
hours
of
operation.
DISTRIBUTOR
DRAIN COVER
CONTAINER