30
Comp. Name
Description
1
Standby LED
Green when the unit is on and orange when in
Standby mode.
2
Standby Button
Puts the unit in or out of Standby mode.
3
Tank Zone LED
Green when the tank is warming and red when
there is an alarm.
4
Hose Zone LED
Green when the hose zone is on and red when
the zone is on alarm.
5
Gun Zone LED
Green when the gun zone is on and red when
there is an alarm.
6
System Ready LED
Green when the system reaches the
programmed temperature.
7
Alarm LED
Red when an alarm goes off.
8
More Button
Increases the value of the selected parameter
9
OK Button
Enter or exit a screen where the selected field
can be edited
10
Right Arrow Button
Moves to the right through editable fields on the
selected menu
11
Less Button
Decreases the value of the selected parameter
12
Left Arrow Button
Moves to the left through editable fields on the
selected menu
13
Settings Screen
Displays the menu screens
14
Configuration Button
Displays the configuration screens
15
Configuration LED
Green when the equipment enters the
configuration screen
16
Temperature Button
Displays the temperature screens
17
Temperature LED
Green when the equipment enters the
temperature screen
18
Release Control Button
Disabled
19
Release Control LED
Disabled
20
On/Off
Cooling/Regression
Button
Puts the equipment in or out of
Cooling/Regression mode. (This mode reduces
the temperature so that the adhesive stays soft,
but not melted when not in operation so it
doesn’t overheat)
21
On/Off
Cooling/Regression LED
Yellow when the unit is in Cooling/Regression
mode.
22
Clock On/Off Button
Turns the timer function on or off
23
Clock On/Off LED
Green when the timer function is activated.
4.2.3.2 On/Off Switch and Standby Mode:
The On/Off switch is at the bottom of the front casing (see photo).