8-2
Valco Cincinnati, Inc.
Section 8 - Troubleshooting and Repair
MM125 - D-90 Hot Melt Unit
Troubleshooting - Continued
Problem
Possible Cause
Possible Solution
Adhesive pressure is too high
Pressure relief valve set too high
Loosen the pressure relief valve
adjustment screw until the desired
pressure is obtained. Replace pressure
relief valve.
No adhesive output
Adhesive not hot enough
Check temperature setting is correct.
Ensure that platen and manifold heaters
have power. Check for blow fuses.
Pump not moving
Check system for ready condition. Check
blown fuse.
Filter
Clean or replace filter.
Cold glue hose or damaged
hosed
Replace hose.
Cold applicator
Check for blown fuse and/or defective
heater.
Clogged applicator
Service applicator system.
Temperature control malfunction
Replace temperature control.
Fuming or smoking of adhesive
Operating temperature exceed
adhesive’s recommended
temperature
Keep setpoint temperature within
recommended range.
Consider another adhesive.
Uneven flow of adhesive to
applicators
Adhesive viscosity is too high
Castings and/or manifold
temperature too low
Raise castings and/or manifold
temperatures in accordance with adhesive
manufacturer’s specifications.
-Wrong adhesive
See adhesive manufacturer’s
recommendations.
Adhesive overheated
Reduce castings and manifold
temperatures in accordance with adhesive
manufacturer’s specifications.
Glue hoses not at the same
temperature
Check temperature setting in the control.
Different pressure drop through
each hose
-Hoses not the same length
Use same length hoses.
-Crimped hose(s)
Replace hose(s).
-Leaking hose(s)
Replace hose(s).
Adhesive supply low
Change drum.
Manifold partially clogged
Clean and flush system.
Nozzles partially clogged
Inspect system for charred adhesive and
foreign matter. Clean and flush system.
Содержание D-90
Страница 20: ...3 2 ValcoMelton Section 3 Basic Features MM125 D 90 Hot Melt Unit Figure 3 2 Basic Features Overview Continued ...
Страница 22: ...3 4 ValcoMelton Section 3 Basic Features MM125 D 90 Hot Melt Unit Manifold Figure 3 3 Manifold ...
Страница 29: ...4 5 ValcoMelton Section 4 Installation MM125 D 90 Hot Melt Unit Electrical Panel ...
Страница 49: ...5 10 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Set Language Continued ...
Страница 50: ...5 11 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Set Temperature Units ...
Страница 52: ...5 13 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Grid Temperature Hose Valve Temperature ...
Страница 53: ...5 14 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Hose Valve Temperature Continued ...
Страница 56: ...5 17 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Ready Delay Time Continued ...
Страница 61: ...5 22 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Beacon 2 Beacon Alarm Setup Continued ...
Страница 67: ...5 28 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Moving Through the Shift Time Day Screens ...
Страница 73: ...5 34 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Sequential Start Valve ...
Страница 109: ...10 3 Section 10 Part Number List ValcoMelton MM125 D 90 Hot Melt Unit Overall Assembly Continued 776XX883 01 dwg ...
Страница 112: ...10 6 Section 10 Part Number List ValcoMelton MM125 D 90 Hot Melt Unit Sheet Metal Assembly 776XX883 03 ...
Страница 113: ...10 7 Section 10 Part Number List ValcoMelton MM125 D 90 Hot Melt Unit 776XX883 03 Sheet Metal Assembly Continued ...
Страница 114: ...10 8 Section 10 Part Number List ValcoMelton MM125 D 90 Hot Melt Unit 776XX883 03 Sheet Metal Assembly Continued ...
Страница 125: ...10 19 Section 10 Part Number List ValcoMelton MM125 D 90 Hot Melt Unit D 90 HMU Electrical Panel Assembly 776XX281 ...
Страница 129: ...10 23 Section 10 Part Number List ValcoMelton MM125 D 90 Hot Melt Unit D90 Hot Melt Unit EQM0690 EQM0690 01 dwg ...
Страница 136: ...10 30 Section 10 Part Number List ValcoMelton MM125 D 90 Hot Melt Unit Electrical Panel Assembly EQM0694 dwg ...
Страница 142: ...A 2 ValcoMelton Appendix A Password Levels MM125 D 90 Hot Melt Unit Setting Level 0 as Default Continued ...
Страница 146: ...C 2 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit 240V 3Ø 029XX435 ...
Страница 147: ...C 3 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit 240V 3Ø 029XX435 ...
Страница 148: ...C 4 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...
Страница 149: ...C 5 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...
Страница 150: ...C 6 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...