4-2
ValcoMelton
Section 4 - Installation
MM125 - D-90 Hot Melt Unit
WARNING!
WARNING!
WARNING!
WARNING!
WARNING!
Electrical connections should be made only by
experienced service personnel! Failure to observe
could result in personal injury, death, or damage to
equipment.
When connecting the supply of electrical power, follow these guidelines:
•
Connect the unit to a “clean” supply of electrical power. Use a
dedicated circuit if possible.
WARNING!
WARNING!
WARNING!
WARNING!
WARNING!
Failure to observe could result in personal injury, death,
or damage to equipment.
When routing low-voltage leads, follow these guidelines:
•
Do not route low-voltage leads in the same conduit as wires
carrying a high-current load.
•
Do not route low-voltage leads adjacent to, or across wires
carrying a high-current load. If low-voltage leads must cross or
run parallel to wires carrying high current, keep the leads at least
6" (152 mm) from high-current wires.
•
Do not splice or solder leads.
•
Trim leads to the required length. Leads should be only as long
as necessary for installation.
•
All wiring should be in conduits or wireways.
Routing Low-
Voltage Leads
Connecting
the Electrical
Power
Installation Kit
An Installation Kit is available for this unit, containing spare fuses, a copy of this
manual on CD and warranty information. For details, see Section 10 - Parts List.
WARNING!
WARNING!
WARNING!
WARNING!
WARNING!
Only experienced service personnel should connect
power to the unit! Failure to observe could result in
personal injury, death, or damage to equipment.
The use of an earth-leakage or ground-fault power
breaker is recommended with this unit. This unit must be
earthed or grounded. Failure to observe could result in
personal injury, death, or damage to equipment.
WARNING!
WARNING!
WARNING!
WARNING!
WARNING!
The external power
source must be turned off before
connecting power to the unit! Failure to observe could
result in personal injury, death, or damage to equipment.
Содержание D-90
Страница 20: ...3 2 ValcoMelton Section 3 Basic Features MM125 D 90 Hot Melt Unit Figure 3 2 Basic Features Overview Continued ...
Страница 22: ...3 4 ValcoMelton Section 3 Basic Features MM125 D 90 Hot Melt Unit Manifold Figure 3 3 Manifold ...
Страница 29: ...4 5 ValcoMelton Section 4 Installation MM125 D 90 Hot Melt Unit Electrical Panel ...
Страница 49: ...5 10 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Set Language Continued ...
Страница 50: ...5 11 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Set Temperature Units ...
Страница 52: ...5 13 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Grid Temperature Hose Valve Temperature ...
Страница 53: ...5 14 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Hose Valve Temperature Continued ...
Страница 56: ...5 17 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Ready Delay Time Continued ...
Страница 61: ...5 22 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Beacon 2 Beacon Alarm Setup Continued ...
Страница 67: ...5 28 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Moving Through the Shift Time Day Screens ...
Страница 73: ...5 34 Valco Cincinnati Inc Section 5 Setup MM125 D 90 Hot Melt Unit Sequential Start Valve ...
Страница 109: ...10 3 Section 10 Part Number List ValcoMelton MM125 D 90 Hot Melt Unit Overall Assembly Continued 776XX883 01 dwg ...
Страница 112: ...10 6 Section 10 Part Number List ValcoMelton MM125 D 90 Hot Melt Unit Sheet Metal Assembly 776XX883 03 ...
Страница 113: ...10 7 Section 10 Part Number List ValcoMelton MM125 D 90 Hot Melt Unit 776XX883 03 Sheet Metal Assembly Continued ...
Страница 114: ...10 8 Section 10 Part Number List ValcoMelton MM125 D 90 Hot Melt Unit 776XX883 03 Sheet Metal Assembly Continued ...
Страница 125: ...10 19 Section 10 Part Number List ValcoMelton MM125 D 90 Hot Melt Unit D 90 HMU Electrical Panel Assembly 776XX281 ...
Страница 129: ...10 23 Section 10 Part Number List ValcoMelton MM125 D 90 Hot Melt Unit D90 Hot Melt Unit EQM0690 EQM0690 01 dwg ...
Страница 136: ...10 30 Section 10 Part Number List ValcoMelton MM125 D 90 Hot Melt Unit Electrical Panel Assembly EQM0694 dwg ...
Страница 142: ...A 2 ValcoMelton Appendix A Password Levels MM125 D 90 Hot Melt Unit Setting Level 0 as Default Continued ...
Страница 146: ...C 2 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit 240V 3Ø 029XX435 ...
Страница 147: ...C 3 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit 240V 3Ø 029XX435 ...
Страница 148: ...C 4 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...
Страница 149: ...C 5 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...
Страница 150: ...C 6 ValcoMelton Appendix C Schematics MM125 D 90 Hot Melt Unit ...