![Vaisala WXT510 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/vaisala/wxt510/wxt510_user-manual_849366050.webp)
User's Guide _______________________________________________________________________
50 ___________________________________________________________________ M210470EN-B
where
a
=
Device address (default =0)
<data fields> =
The measured parameters in selected units, separated
with '+' marks (or - marks in case of parameter values).
<cr><lf>
=
Response terminator
NOTE
aD0
command can also be used to break the measurement in progress
started with commands
aM,
aMC,
aC
or
aCC
.
Examples of aM, aC and aD
commands:
NOTE
The parameter order in the output is as presented in the parameter selection
setting field, see Chapter 8,
Setting fields
The device address is 0 in all examples.
Example 1:
Start a wind measurement and request the data (all 6 wind parameters
are enabled in the message):
0M1!
00036<cr><lf>
(measurement ready in 3 seconds and 6
parameters available)
0<cr><lf>
(measurement completed)
0D0!
0+339+018+030+0.1+0.1+0.1<cr><lf>
Example 2:
Start a concurrent pressure, humidity and temperature measurement
and request the data:
0C2!
000503<cr><lf>
(measurement ready in 5 seconds and 3
parameters available)
0D0!
0+23.6+29.5+1009.5<cr><lf>
Example 3:
Start a precipitation measurement and request the data:
0M3!
00006<cr><lf>
(6 parameters available immediately, thus the
device address is not sent)
0D0!
0+0.15+20+0.0+0.0+0+0.0<cr><lf>