Measurement reset (aXZM)
This command is used to interrupt all ongoing measurements of the
transmitter and start them from the beginning.
Command format in ASCII and NMEA 0183:
aXZM<cr><lf>
Command format in SDI-12:
aXZM!
where
a
=
Device address (default= 0)
XZM
= Measurement break command
<cr><lf>
=
Command terminator in ASCII and NMEA 0183
!
=
Command terminator in SDI-12
The response in ASCII:
0XZM<cr><lf>
OTX,Measurement reset<cr><lf>
The response in SDI-12: (No response).
0XZM!
0
The response in NMEA 0183:
0XZM<cr><lf>
$WITXT,01,01,09,Measurement reset*50<cr><lf>