![Vaisala MAWS101 Скачать руководство пользователя страница 90](http://html1.mh-extra.com/html/vaisala/maws101/maws101_user-manual_3205925090.webp)
User's Guide _______________________________________________________________________
88 ___________________________________________________________________ M210243en-A
0105-071
Figure 84
Mounting QLW101 to a Pole
To the Sensor Arm
For installation to the sensor arm, use the provided hexagon bolts and
lock washers. Tighten the hex nuts with a 6 mm Allen key. See Figure
85 below.
0105-072
Figure 85
QLW101 Installed on Sensor Arm
Finalizing the Installation
1.
Install the sensor as shown in Figure 83 on page 87, in Figure 84
above, or in Figure 85 above.
2.
Pull the sensor cable close to the tube's lower base. Cut the cable
to a proper length. Thread the cable through the connector parts
in the indicated order 1-2-3-4. See Figure 56 on page 66.
3.
Strip the sensor cable wires and connect them to connector
terminals according to Table 13 on page 89. Assemble the
connector.