![Vaisala MAWS101 Скачать руководство пользователя страница 170](http://html1.mh-extra.com/html/vaisala/maws101/maws101_user-manual_3205925170.webp)
User's Guide _______________________________________________________________________
168 __________________________________________________________________ M210243en-A
Figure 127 on page 167 provides a schematic wiring diagram for the
combination of the RS-485 and RS-232 connection. The correct
jumper settings for the channel B are listed in Table 38 below.
Table 38
The Jumper Settings for Channel B in the RS-232
Mode
Jumper
Connected
Pins
Function
X3
2-3
1-4
X6
2-5
Sets the RS-232 mode active for the channel B.
X5
None
The line terminating resistor is not in use at all.
DMX501
The DMX501 modem module can be configured for point-to-point
line or for a multidrop modem network. If a modem is configured for
multidrop use, the outgoing carrier is valid only during transmission.
If MAWS is the master in the multidrop network, DMX501 can be
normally configured for point-to-point use.
Figure 128
DMX501 Wiring Diagram