![Vaisala MAWS101 Скачать руководство пользователя страница 130](http://html1.mh-extra.com/html/vaisala/maws101/maws101_user-manual_3205925130.webp)
User's Guide _______________________________________________________________________
128 __________________________________________________________________ M210243en-A
data from the internal log directory to the memory card daily at
midnight, the default time is 00:00:30. The data is being written, when
the LED on the logger cover to the left of the external memory card is
constantly on.
CAUTION
The memory card must not be removed from MAWS while data is
being written or the data may be lost.
When a new memory card is inserted into MAWS, the software
checks that the card is ready for use. The status of the memory card is
indicated by a LED. Table 24 below describes the different blinking
sequences and the card conditions they indicate.
Table 24
LED Blinking Sequences and Card Status Options
Blinking Sequence
Card Status
Long-long
The card is OK.
Constantly on
Data is being written.
Short-short-short for 5 seconds
The card is unformatted or
corrupted.
Resetting MAWS
To reset MAWS,
give the command
reset
(recommended) or press the
reset button (see Figure 4 on page 24).
A short reset (pressing the reset button quickly) performs the same
reset as giving the command and starts the program again. A long
reset (pressing the reset button and keeping it down for a few seconds)
restarts the program with a so-called "blank" setup. A blank setup
does not run a configuration file.
The blank setup may be useful if configuration is somehow defective
and does not allow the user to open a terminal connection. When the
blank setup is run, MAWS communication parameters are restored to
their defaults: COM0, 9600, N, 8, N, 1.