Chapter 3 ________________________________________________________________ Installation
VAISALA ________________________________________________________________________ 75
Installing Air Temperature and
Relative Humidity Sensor
Figure 66
QMH101 Probe and the Radiation Shield
Install the QMH101 Temperature and Relative Humidity Sensor in the
following way:
1.
Install the radiation shield with the support on the mounting arm
using the two screws.
2.
Slide the temperature and humidity probe into the shield.
3.
Tighten the fastening ring.
4.
Guide the sensor cable through the sensor arm opening.
5.
Connect the signal cable to the upper base plate of the tube. See
Table 11 on page 72.
Installing Rain Gauges
QMR101
QMR101 is usually installed on the same sensor arm with the
temperature and humidity probe. QMR101 should be attached to a
sensor arm in the following way:
1.
Attach the mounting plates (1) to the sensor (2), if not already in
place.