![Vaisala MAWS101 Скачать руководство пользователя страница 156](http://html1.mh-extra.com/html/vaisala/maws101/maws101_user-manual_3205925156.webp)
User's Guide _______________________________________________________________________
154 __________________________________________________________________ M210243en-A
Example:
/ W> warnings
Warning: Break
occurred 9 times first in uart.cpp[84]
during thread: 00019F60 [AbsTimerT]
object pointer: 106C [component: COM0]
Warning: Frame
occurred 14 times first in uart.cpp[83]
during thread: 00019F60 [AbsTimerT]
object pointer: 106C [component: COM0]
The Break and Frame warnings mean that most likely you have turned
your PC off and on again. This causes no trouble and you can clear the
warnings.
Warning: Device reset
occurred 1 times first in
c:/libs/MAWS/adcl/kernel/idle.cpp[52]
during thread: 00001694 [Idle]
object pointer: 163C [component: Idle]
The warning above means that you have reset MAWS. This causes no
trouble and you can clear the warning. If you have not reset MAWS
and the warning still occurs, contact Vaisala technical support (see
section Getting Help on page 159).
Warning: Data missing
occurred 2 times first in
h:/MAWS/software/adcl/report/confrep.cpp[414]
during thread: 00019C0C [AbsTimerT]
object pointer: 33A94 [component: MyRep1]
If you receive this warning, check that
sname
,
pslevel
, and
altitude
are set.
To see active errors, type
errors
. To clear active errors, type
errors
clear
. Errors indicate that there is something wrong with the sensors
or configuration. Write down the error information and contact
technical support.