5.3.5 Showing/Hiding Sensor Site Numbers
To select if the sensor site numbers are displayed inside the sensor site symbols, toggle the
Show site info
/
Hide site info
button.
5.3.6 Testing Alarms
To test how the alarms will be displayed, click the
Test
button. All possible alerts are shown
as blinking alert boxes.
5.4 Troubleshooting Graphical Windshear
Display
Table 18 Troubleshooting Graphical Windshear Display
Problem
Probable Cause
Solution
There is a cross across the
sensor site symbol.
There is no connection to the sensor and the wind
speed or wind direction data are missing. There might
be technical problems with the sensor.
Contact maintenance.
Slashes (///) are displayed
in the alert box.
Connection to LLWAS algorithm is lost.
Contact maintenance.