Inspection and maintenance
Installation and maintenance instructions ecoTEC plus 0020134833_01
67
12
12.4.6
Installing the compact thermal module
a
Danger!
Risk of death and risk of damage caused
by hot flue gas!
If you do not renew the seal and the self-
locking nuts on the burner door, hot flue
gases may escape and cause personal
injury and material damage.
>
Replace the seal each time you open the
burner door.
>
Replace the self-securing nuts each time
you open the burner door.
>
If the burner flange insulation on the
module shows signs of damage other
than small cracks it must be replaced
(article number 193 595).
1
2
4
3
5
9
8
7
6
12.9
Installing the compact thermal module
>
Attach the compact thermal module (
2, ¬ fig. 12.9
) to
the heat exchanger (
1, ¬ fig. 12.9
).
>
Tighten the four nuts (
9, ¬ fig. 12.9
) crosswise until the
burner door fits closely and uniformly onto the mating
surfaces (If a torque spanner is available, set at 6 Nm).
>
Attach the plug of the ignition line (
7, ¬ fig. 12.9
) and
the ground connection (
8, ¬ fig. 12.9
) to the ignition
electrode.
>
Attach the plug (
4, ¬ fig. 12.9
) to the fan motor.
>
Attach the three plugs to the gas valve (
5, ¬ fig. 12.9
).
>
Attach the cable to the Venturi (
3, ¬ fig. 12.9
).
12.10
Tightening the cap nuts on the gas valve
>
Connect the gas supply (
6, ¬ Fig. 12.9
) to the gas valve
with a new seal.
When the cap nuts are being screwed to the gas valve,
counterhold the opposite side of the gas valve or screw
both cap nuts to the gas valve simultaneously.
>
Open the gas isolator cock on the boiler and ensure
there are no leaks.
>
Check that the sealing ring in the air intake pipe is posi-
tioned correctly in the seal seat.
>
Insert the air intake pipe (
1, ¬ fig. 12.3
) back into the
intake stub.
>
Attach the air intake pipe using the retaining screw (
2,
¬ fig. 12.3
).
Содержание ecoTEC plus VUI