Installation
Installation and maintenance instructions ecoTEC plus 0020134833_01
21
4
4.8
Removing/fitting the front casing
2
1
4.7 Removing the front casing
Removing the front casing
>
Loosen the screw (
1
) on the bottom of the boiler using a
screwdriver or small spanner.
>
Push in both retaining clips (
2
) on the underside of the
boiler so that the front casing is released.
>
Pull the front casing forwards using the bottom edge.
>
Lift the front casing upwards from the bracket.
Fitting the front casing
>
Place the front casing on the upper brackets.
>
Push the front casing onto the boiler until both retaining
clips (
2
) snap into place at the front casing.
>
Secure the front casing by screwing in the bolt (
1
) on the
underside of the boiler.
4.9
Removing/fitting the side panel
You can also remove a side panel for installation or mainte-
nance purposes.
b
Caution.
Risk of damage caused by mechanical
tension.
Removing
both
side panels may cause
mechanical distortion in the boiler, which
can cause damage to the piping, for exam-
ple, and potentially result in leaks.
>
Always only remove
one
side panel,
never both side panels at the same time.
1.
3.
4.
2.
4.8 Removing/fitting the side panel
b
Caution
Risk of damage to the side panel.
Unscrewed side panels that are merely sus-
pended from the back wall can fall down.
>
Hold onto the side panel when you are
unscrewing it, and always remove it from
the boiler.
>
Fold the electronics box (
1
) forwards.
>
Unscrew the two bolts (
2.
) from the top and bottom of
the side panel.
>
Hold onto the side panel (
3.
) when doing this.
>
Swivel the side panel outwards and remove it from below
by pulling it downwards (
4.
).
>
Install the side panel in reverse order.
Содержание ecoTEC plus VUI