Adapting the boiler to the heating installation
54
Installation and maintenance instructions ecoTEC plus 0020134833_01
11
Code
Parameters
Adjustable values
Factory set-
ting
Your own
setting
D.090
Status of digital controller
recognised, not recognised
Not adjustable
D.091
Status DCF with external sensor con-
nected
No reception
Reception
Synchronised
Valid
Not adjustable
D.092
actoSTOR module recognition
-
Not connected
-
Connection error: No communication via PeBus, acto-
STOR module detected previously
-
Connection active
D.093
Setting of device specific number (DSN)
Setting range: 0 to 99
D.094
Delete fault history
Delete fault list
D.095
Software version of PeBUS components
PCB (BMU)
Display(AI)
actoSTOR(APC)
HBI/VR34
Not adjustable
D.096
Factory setting
Reset all adjustable parameters to default setting
D.098
Value of coding resistors for gas group
and output range
Display xx.yy
xx = Coding resistor 1 in cable harness for output
range:
11 = VUI 937
yy = Coding resistor 2 on PCB for gas group:
02 = P-Gas
03 = H Gas
Not adjustable
11.1 Diagnostics codes (continued)
11.1.1
Setting the heating partial load
The heating partial load of the Vaillant ecoTEC plus boiler is
factory set to "auto". This means that the boiler automati-
cally determines the optimum heating output depending on
the current heat demand of the system. A setting is nor-
mally no longer required. If you still want to set a fixed
maximum heating partial load, you can set a value under
diagnostics code "D.000" which equates to the boiler out-
put in kW.
11.1.2
Setting pump overrun time and pump
operating mode
The pump overrun time for the heating mode is set at the
factory to a value of 5 minutes. You can set the pump over-
run time under diagnostics code "D.001" within the range of
1 minute to 60 minutes. You can set a different pump oper-
ating mode under diagnostics code "D.018". Here you have
the choice between Eco and Comfort.
Comfort (continuously operating pump)
The internal pump is switched on when the heating flow
temperature is not at "Heating off"(
¬ Operating instruc-
tions)
and the heating requirement is enabled via an exter-
nal controller.