Example:
Transfer delay between the AC drive and the PC = 600 ms
The value of par. 6.7.3 is set to 1200 ms (2 x 600, sending delay + receiving delay)
The corresponding setting shall be entered in the Misc -part of the file NCDrive.ini:
Retries = 5
AckTimeOut = 1200
TimeOut = 6000
It must also be considered that intervals shorter than the AckTimeOut-time cannot be used in NC-Drive
monitoring.
Enter the edit mode by pushing the
Menu button right
. Use the
Browser buttons
to change the
acknowledgement time. Accept the change with the
Enter button
or return to the previous level with the
Menu button left
.
Figure 7-23. HMI acknowledge timeout
Number of retries to receive HMI acknowledgement (P6.7.4)
With this parameter you can set the number of times the drive will try receive acknowledgement if this
does not succeed within the acknowledgement time (P6.7.3) or if the received acknowledgement is faulty.
Enter the edit mode by pushing the
Menu button right
. The present value shown starts to blink. Use the
Browser buttons
to change the amount of retries. Accept the change with the
Enter button
or return to the
previous level with the
Menu button left
.
See Figure 7-23 for the procedure of changing the value.
7.3.6.8
System info
In the
System info submenu
(S6.8) you can find AC drive-related hardware and software information as
well as operation-related information.
Total counters (S6.8.1)
In the
Total counters
page (S6.8.1) you can find information related to the AC drive operation times, i.e. the
total numbers of MWh, operation days and operation hours passed so far. Unlike the counters in the Trip
counters , these counters cannot be reset.
Note! The Power On time counter (days and hours) runs always, when the power is on.
Page
Counter
Example
C6.8.1.1.
MWh counter
C6.8.1.2.
Power On day counter
Value on display is
1.013. The drive has operated
for 1 year and 13 days.
C6.8.1.3.
Power On hour counter
Value on display is 7:05:16. The drive has
operated for 7 hours 5 minutes and 16 seconds.
Table 7-7. Counter pages
READY
I/O term
200ms
READY
I/O term
enter
200ms
HMI ACK timeout
HMI ACK timeout
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Содержание NX_ 0003 5
Страница 11: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com...
Страница 12: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com...
Страница 13: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com...
Страница 52: ...52 vacon CABLING AND CONNECTIONS 6 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com...