144
•
vacon
parameter descriptions
9
General status word (output process data)
Information about the status of the device and messages is indicated in the General
status word. The General status word is composed of 16 bits the meanings of which
are described in the table below:
Actual speed (output process data)
This is actual speed of the frequency converter. The scaling is -10000...10000. The
value is scaled in percentage of the frequency area between set minimum and max-
imum frequency.
Control word (input process data)
The three first bits of the control word are used to control the frequency converter.
By using control word it is possible to control the operation of the drive. The mean-
ings of the bits of control word are explained in the table below
:
Bit
Description
Value = 0
Value = 1
B0, RDY
Drive not ready
Drive ready
B1, RUN
Stop
Run
B2, DIR
Clockwise
Counter-clockwise
B3, FLT
No fault
Fault active
B4, W
No alarm
Alarm active
B5, AREF
Ramping
Speed reference reached
B6, Z
-
Drive is running at zero speed
B7, F
-
Fieldbus control active
B8 - B12
-
-
Bit
Control place
I/O
PC tool
Keypad
Fieldbus
B13
1
0
0
0
B14
0
1
1
0
B15
0
1
0
1
Table 9.7: General status word (output process data)
Bit
Description
Value = 0
Value = 1
B0, RUN
Stop
Run
B1, DIR
Clockwise
Counter-clockwise
B2, RST
Rising edge of this bit will reset active fault
B5, Quick ramp time
Normal deceleration ramp time
Quick deceleration ramp time
Table 9.8: Control word (input process data)
Содержание 20
Страница 1: ...vacon 20 ac drives complete user manual ...
Страница 2: ......
Страница 6: ...1 ...
Страница 12: ...6 vacon safety 1 ...
Страница 20: ...14 vacon installation 3 Figure 3 7 Flange mounting depth dimensions for MI4 and MI5 Unit mm MI5 MI4 ...
Страница 27: ...installation vacon 21 3 ...
Страница 28: ...22 vacon installation 3 MI1 MI5 3P 230 V POWER LOSS ...
Страница 29: ...installation vacon 23 3 ...
Страница 30: ...24 vacon installation 3 ...
Страница 31: ...installation vacon 25 3 MI1 MI3 1P 230 V POWER LOSS ...
Страница 32: ...26 vacon installation 3 ...
Страница 40: ...34 vacon installation 3 Figure 3 23 Open the lid MI1 MI3 Figure 3 24 Open the lid MI4 MI5 ...
Страница 43: ...installation vacon 37 3 4 5 6 ...
Страница 52: ...46 vacon installation 3 ...
Страница 76: ...70 vacon control panel 7 ...
Страница 104: ...98 vacon parameters 8 ...
Страница 152: ...146 vacon parameter descriptions 9 ...
Страница 158: ...152 vacon technical data 10 ...
Страница 159: ......
Страница 160: ...Rev E2 Document ID ...