CONTROL UNIT INDICATORS (LEDS)
The highlighted boxes indicate the state of the LEDs when the
gate is resting.
CABLE GLAND ASSEMBLY
The casing can accept 4 cable glands in the special
easy-break housings.
The type of cable gland is indicated in the figure.
PLEASE NOTE:
• Remove the electronic circuit board before drill
the casing.
• Drill the container using a suitably sized cutter,
according to the dimensions of the cable gland.
• Fix the cable glands using the special nuts.
LED
ON
OFF
START
START input closed
START input open
IN2
START P. input closed
START P. input open
STOP
STOP input closed
STOP input open
PHOTO
PHOTO input closed
PHOTO input open
EDGE
Standard edge
EDGE input closed (edge
not pressed)
EDGE input open (edge
pressed)
Resistive rubber edge
EDGE input closed
(edge pressed)
EDGE input open
(fault)
Edge NO pressed: 8K2
between EDGE input and
common (-)
FCA
Opening limit switch closed Opening limit switch open
FCC
Closing limit switch closed
Closing limit switch open
mains
Control unit powered-up
Control unit NOT powered-up
overload
Accessory power supply
overload
Accessory power supply within
normal operational limits
9
ADJUSTMENT OF THE POWER AND
OPERATIONAL TIMES
The power and operating times may be adjusted by means of 3
trimmers located on the control unit:
POWER:
motor power.
WORK:
motor operating time (2 - 120 seconds).
PLEASE NOTE:
it is recommended that operating times be
set with the slow down function disabled (DIP 5 OFF).
WARNING: the adjustment of times has to be made
when the gate is still
PAUSE:
pause time before automatic re-closure
(2 - 150 seconds).