ELECTRICAL CONNECTION TABLE
L1
Antenna
L2
Antenna shield
L3
Opening command for a standard connection device
with switch normally open.
L4
Pedestrian opening command for a standard
connection device with switch normally open.
L5
STOP command. N.C. switch
L6
Photocell. N.C. switch
L7
Edge. Switch N.C. or resistive rubber edge
L8
Commands common (-) line
L9 - L10
24 VAC power output for photocells and other
accessories
L10 - L11
Power supply for functional test TX photocell
C1
Motor open
C2
Motor common
C3
Motor close
D1 - D2
Courtesy light timer activation switch
D3 - D4
230V - 40W / 120V - 40W blinker
N
230V / 120V power supply - neutral
L
230V / 120V power supply - phase
A
Limit switch open. N.C. switch
B
Limit switch closed. N.C. switch
C
NOT USED
D
Limit switch common (-) line
J1
NOT USED
PLEASE NOTE: If not used, the normally closed inputs (STOP, PHOTO, EDGE) must be jumpered with the commands
common line COM (-)
If not used, the open limit switch FCA (A) and close limit switch FCC (B) inputs must be jumpered with the limit switch
common line (D)
J1
8